Key result
Heart-to-finger pulse wave conduction time measurements in healthy young adults yielded minimum detectable percentage changes of 7.8%, 10.5%, and 13.6% for p-values of 0.05, 0.01, and 0.001.
Why the study?
Determining what constitutes a statistically significant change in arterial stiffness measurements is an important clinical consideration, prompting evaluation of heart-to-finger pulse wave conduction time variability and minimum detectable change estimates.
Observational (n=10)
This study provides minimum detectable change estimates for heart-to-finger pulse wave conduction time, which can help in planning experiments and assessing the validity of clinical outcomes involving pulse wave velocity.
Answers are grounded in this paper and cite their sources.
MDC estimates for PWCT variability inform arterial stiffness monitoring; leaves open clinical adoption pending prospective validation.
BACKGROUND: Pulse wave velocity (PWV) measurements are the gold standard for assessing arterial stiffness and estimating time or treatment-related changes in cardiovascular status. What constitutes a statistically significant change is an important clinical consideration. This study aimed to describe the variability of heart-to-finger pulse wave conduction time (PWCT) to provide estimates of the minimum detectable change (MDC) dependent on the number of PWCT samples used. MATERIALS AND METHODS: Heart-to-finger PWCT was measured based on the time delay between the peak of the EKG R-wave and arterial pulse arrival at the left hand index finger as measured by a photoplethysmographic sensor. Measurements were done in 10 young adults (25.7 ± 1.2 years) while supine for 45 min. Depending on the subject's heart rate, these measurements yielded 2430 to 3750 contiguous PWCT for analysis. The variability in these PWCTs was used to determine the minimal detectable percentage change for specified p-values of 0.05, 0.01, and 0.001. RESULTS: Sample sizes of 10, 30, 50, or 300 contiguous PWCTs yield similar MDC estimates for a given targeted p-value. The MDC% depended on the chosen p-value, with values of MDC% for p-values of 0.05, 0.01, and 0.001 being 7.8%, 10.5%, and 13.6%. CONCLUSIONS: The estimates may help plan experiments when changes or differences in PWCT or PWV are of interest. Also, these MDC estimates may help assess the validity of clinical study outcomes if PWV changes are outcome measures. The main limitation of the estimates is that they are based on 10 healthy subjects.
No takes yet. Share an insight, caveat, or question.
Harvey N. Mayrovitz (2025) conducted an observational in Cardiovascular-healthy (n=10). Heart-to-finger pulse wave conduction time (PWCT) measurement was evaluated on Minimum detectable change (MDC) percentage. Heart-to-finger pulse wave conduction time measurements in healthy young adults yielded minimum detectable percentage changes of 7.8%, 10.5%, and 13.6% for p-values of 0.05, 0.01, and 0.001.