Key result
Noninvasive Hemodynamic Cardiac Profiler closely matches MRI ventricular volume curves, achieving ICCs >0.8.
Why the study?
The study was conducted to validate ventricular volume-time curves obtained from the hemodynamic cardiac profiler against volume-time curves from MRI in healthy volunteers.
Does the Hemodynamic Cardiac Profiler (HCP) accurately measure left- and right-ventricular volume dynamics compared to cardiac MRI in healthy adults?
Cross-Sectional (n=6)
No
Does the Hemodynamic Cardiac Profiler (HCP) accurately measure left- and right-ventricular volume dynamics compared to cardiac MRI in healthy adults?
Answers are grounded in this paper and cite their sources.
The Hemodynamic Cardiac Profiler (HCP) provides reliable, non-invasive, and operator-independent measurements of ventricular volume dynamics that closely agree with MRI, suggesting its potential utility as an accessible diagnostic screening and monitoring tool.
Background. The hemodynamic cardiac profiler (HCP) is a new, non-invasive, operator-independent screening tool that uses six independent electrode pairs on the frontal thoracic skin, and a low-intensity, patient-safe, high-frequency applied alternating current to measure ventricular volume dynamics during the cardiac cycle for producing ventricular volume-time curves (VTCs). Objective. To validate VTCs from HCP against VTCs from MRI in healthy volunteers. Approach. Left- and right-ventricular VTCs were obtained by HCP and MRI in six healthy participants in supine position. Since HCP is not compatible with MRI, HCP measurements were performed within 20 min before and immediately after MRI, without intermittent fluid intake or release by participants. Intraclass correlation coefficients (ICCs) were calculated to validate HCP-VTC against MRI-VTC and to assess repeatability of HCP measurements before and after MRI. Bland–Altman plots were used to assess agreement between relevant HCP- and MRI-VTC-derived parameters. Precision of HCP’s measurement of VTC-derived parameters was determined for each study participant by calculating the coefficients of variation and repeatability coefficients. Main results. Left- and right-ventricular VTC ICCs between HCP and MRI were >0.8 for all study participants, indicating excellent agreement between HCP-VTCs and MRI-VTCs. Mean (range) ICC of HCP right-ventricular VTC versus MRI right-ventricular VTC was 0.94 (0.88–0.99) and seemed to be slightly higher than the mean ICC of HCP left-ventricular VTC versus MRI-VTC (0.91 (0.80–0.96)). The repeatability coefficient for HCP’s measurement of systolic time (tSys) was 45.0 ms at a mean value of 282.9 ± 26.3 ms. Repeatability of biventricular HCP-VTCs was excellent (ICC 0.96 (0.907–0.995)). Significance. Ventricular volume dynamics measured by HCP-VTCs show excellent agreement with VTCs measured by MRI. Since abnormal tSys is a sign of numerous cardiac diseases, the HCP may potentially be used as a diagnostic screening tool.
No takes yet. Share an insight, caveat, or question.
Konings et al. (2023) conducted a cross-sectional in Healthy volunteers (n=6). Hemodynamic Cardiac Profiler (HCP) vs. Magnetic Resonance Imaging (MRI) was evaluated on Agreement between left- and right-ventricular volume-time curves (VTCs) measured by HCP and MRI (ICC >0.8 for all participants). The Hemodynamic Cardiac Profiler (HCP) accurately measured ventricular volume dynamics, demonstrating excellent agreement with MRI with intraclass correlation coefficients >0.8 for all left- and right-ventricular volume-time curves.