Key result
Twelve commercial real-time PCR kits for African swine fever virus demonstrated an overall specificity of 100% and sensitivity between 95% and 100%.
Why the study?
Commercial real-time PCR kits for African swine fever virus detection have entered the market and undergone general validation, but have never been compared to each other.
Do commercial real-time PCR kits perform comparably to an OIE-recommended method for detecting the African swine fever virus genome?
Do commercial real-time PCR kits perform comparably to an OIE-recommended method for detecting the African swine fever virus genome?
Twelve commercial real-time PCR kits demonstrated high sensitivity and specificity for detecting African swine fever virus, indicating they are fit for diagnostic purposes.
Answers are grounded in this paper and cite their sources.
Variable performance among commercial ASF qPCR kits warrants caution in selection; leaves open standardized diagnostic protocols.
African swine fever (ASF) is a major threat to pig production, and real-time PCR (qPCR) protocols are an integral part of ASF laboratory diagnosis. With the pandemic spread of ASF, commercial kits have risen on the market. In Germany, the kits have to go through an approval process and thus, general validation can be assumed. However, they have never been compared to each other. In this study, 12 commercial PCR kits were compared to an OIE-recommended method. Samples representing different matrices, genome loads, and genotypes were included in a panel that was tested under diagnostic conditions. The comparison included user-friendliness, internal controls, and the time required. All qPCRs were able to detect ASFV genome in different matrices across all genotypes and disease courses. With one exception, there were no significant differences when comparing the overall mean. The overall specificity was 100% (95% CI 87.66-100), and the sensitivity was between 95% and 100% (95% CI 91.11-100). As can be expected, variability concerned samples with low genome load. To conclude, all tests were fit for purpose. The test system can therefore be chosen based on compatibility and prioritization of the internal control system.
No takes yet. Share an insight, caveat, or question.
Pikalo et al. (2022) studied African swine fever. 12 commercial real-time PCR kits vs. OIE-recommended method was evaluated on Detection of ASFV genome. Twelve commercial real-time PCR kits for African swine fever virus demonstrated an overall specificity of 100% and sensitivity between 95% and 100%.
Synapse has enriched 10 related papers. Consider them for comparative context: