Key result
Manual measurement of mitral chordae strongly correlated with echocardiographic measurement, yielding the predictive model EM = 0.87 × MM + 4 for use when echocardiography is contraindicated.
Why the study?
In mitral insufficiency, determining chordal length is essential for repair, but echocardiography is sometimes not feasible, creating a need to predict echographic measurements from intraoperative manual measurements.
Can manual measurement of mitral valve chordae intraoperatively predict echographic measurement in patients undergoing mitral valve repair?
Observational (n=191)
No
Can manual measurement of mitral valve chordae intraoperatively predict echographic measurement in patients undergoing mitral valve repair?
A mathematical model (EM = 0.87x MM + 4) can accurately predict echographic measurements of mitral chordae from intraoperative manual measurements when TEE is not feasible.
Answers are grounded in this paper and cite their sources.
May enable chordal sizing in mitral repair when TEE unavailable; hypothesis-generating and requires prospective validation.
Objective In mitral insufficiency, trans-esophageal echocardiography (TEE) analysis of the mitral valve is an indispensable and irreplaceable examination to establish precisely the type of surgical repair to be performed and the exact length of neo-chordae to be used for an anatomical repair. The aim of our study is to find a predictive model of the Echographic Measurement (EM) variable according to the Manual Measurement (MM) variable of the mitral valve chordae, when the echocardiography measurement is not feasible. Patients and methods This is a retrospective study on 191 patients undergoing mitral valve repair. The sex ratio (M/F) is 2.13 (130 men and 61 women). The collection of data of mitral chordae measurements performed echographically in preoperatively conditions, and then manually in intraoperatively conditions from January 2008 to December 2016 was made from the medical records of patients at the cardiology and cardiac surgery department of the University Hospital Center of Amiens in Picardy. Results For this study 191 patients of mean age of 68 ± 13 years were included. The averages of the MM and EM of the mitral chordae were respectively 23 ± 2.5 mm and 24 ± 2.4 mm. The Pearson correlation coefficient was 0.897 (p-value <10⁻⁴) showing a strong positive correlation between MM and EM. The results of the linear regression allow us to found the following mathematical model : EM = 0.87x MM + 4. Conclusions When patients have a contraindication to transesophageal echocardiography or when TEE is not feasible, manual measurement is performed during the surgery. By using the values obtained (MM) in the model, it is possible to predict the corresponding echographic measurements. This allows us to achieve the mitral tendinous chordae substitution with a very high precision. Trial registration Retrospectively registered.
No takes yet. Share an insight, caveat, or question.
Gun et al. (2021) conducted an observational in Severe mitral insufficiency (n=191). Manual measurement of mitral chordae vs. Echocardiographic measurement was evaluated on Correlation between manual measurement (MM) and echocardiographic measurement (EM) of mitral chordae (r = 0.897, 95% CI 0.865-0.921, p=<0.0001). Manual measurement of mitral chordae strongly correlated with echocardiographic measurement, yielding the predictive model EM = 0.87 × MM + 4 for use when echocardiography is contraindicated.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: