Key result
Significant beat-to-beat repolarization variations before arrhythmia onset were detected in 35% (13 of 37) of VT/VF episodes compared to baseline reference EGMs.
Why the study?
Does analysis of beat-to-beat repolarization variations on ICD-stored electrograms predict the onset of ventricular arrhythmias in patients with ICDs?
Observational (n=57)
Does analysis of beat-to-beat repolarization variations on ICD-stored electrograms predict the onset of ventricular arrhythmias in patients with ICDs?
Detection of beat-by-beat repolarization variations in ICD-stored electrograms is feasible and may serve as a predictor for the onset of ventricular arrhythmias.
Beat-to-beat repolarization variations on ICD electrograms were associated with imminent VT/VF; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: The aim of the Endocardial T-Wave Alternans Study was to prospectively assess the presence of T-wave alternans (TWA) or beat-to-beat repolarization changes on implantable cardioverter-defibrillator (ICD)-stored electrograms (EGMs) immediately preceding the onset of spontaneous ventricular tachycardia (VT) or fibrillation (VF). METHODS: Thirty-seven VT/VF episodes were compared to 116 baseline reference EGMs from the same 57 patients. A Bayesian model was used to estimate the T-wave waveform in each cardiac beat and a set of 10 parameters was selected to segment each detected T wave. Beat-by-beat differences in each T-wave parameter were computed using the absolute value of the difference between each beat and the following one. Fisher criterion was used for determining the most discriminant T-wave parameters, then top-M ranked parameters yielding a normalized cumulative Fisher score > 95% were selected, and analysis was applied on these selected parameters. Simulated TWA EGMs were used to validate the algorithm. RESULTS: In the simulation study, TWA was detectable even in the case of the smallest simulated alternans of 25 μV. In 13 of the 37 episodes (35%) occurring in nine of 16 patients, significant larger beat-to-beat variations before arrhythmia onset were detected compared to their respective references (median one positive episode per patient). Parameters including the T-wave apex amplitude seem the more discriminant parameters. CONCLUSIONS: Detection of beat-by-beat repolarization variations in ICD-stored EGMs is feasible in a significant subset of cases and may be used for predicting the onset of ventricular arrhythmias.
No takes yet. Share an insight, caveat, or question.
Maury et al. (2014) conducted an observational in Ventricular tachycardia or fibrillation (n=57). Beat-to-beat repolarization variations on ICD-stored EGMs vs. Baseline reference EGMs was evaluated on Significant larger beat-to-beat variations before arrhythmia onset. Significant beat-to-beat repolarization variations before arrhythmia onset were detected in 35% (13 of 37) of VT/VF episodes compared to baseline reference EGMs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: