Key result
Exercise-induced T-wave alternans at zero workload discriminated ICD patients who developed ventricular arrhythmias from controls, but not at maximal workload.
Why the study?
Does exercise-induced T-wave alternans predict the occurrence of ventricular arrhythmias in patients with an implanted cardiac defibrillator?
Case-Control (n=67)
Does exercise-induced T-wave alternans predict the occurrence of ventricular arrhythmias in patients with an implanted cardiac defibrillator?
T-wave alternans measured at low heart rates (zero workload) may have better predictive power for ventricular arrhythmias in ICD patients than at maximal workload.
Answers are grounded in this paper and cite their sources.
May support low-workload TWA for arrhythmia prediction in ICD patients; hypothesis-generating and requires prospective validation.
The power of exercise-induced T-wave alternans (TWA) to predict the occurrence of ventricular arrhythmias was evaluated in 67 patients with an implanted cardiac defibrillator (ICD). During the 4-year follow-up, electrocardiographic (ECG) tracings were recorded in a bicycle ergometer test with increasing workload ranging from zero (NoWL) to the patient's maximal capacity (MaxWL). After the follow-up, patients were classified as either ICD_Cases (n = 29), if developed ventricular tachycardia/fibrillation, or ICD_Controls (n = 38). TWA was quantified using our heart-rate adaptive match filter. Compared to NoWL, MaxWL was characterized by faster heart rates and higher TWA in both ICD_Cases (12-18 μ V vs. 20-39 μ V; P < 0.05) and ICD_Controls (9-15 μ V vs. 20-32 μ V; P < 0.05). Still, TWA was able to discriminate the two ICD groups during NoWL (sensitivity = 59-83%, specificity = 53-84%) but not MaxWL (sensitivity = 55-69%, specificity = 39-74%). Thus, this retrospective observational case-control study suggests that TWA's predictive power for the occurrence of ventricular arrhythmias could increase at low heart rates.
No takes yet. Share an insight, caveat, or question.
Burattini et al. (2013) conducted a case-control in Implanted cardiac defibrillator (ICD) (n=67). Exercise-induced T-wave alternans (TWA) vs. ICD_Controls (no ventricular arrhythmias) was evaluated on Occurrence of ventricular arrhythmias (ventricular tachycardia/fibrillation). Exercise-induced T-wave alternans at zero workload discriminated ICD patients who developed ventricular arrhythmias from controls, but not at maximal workload.
Synapse has enriched 10 related papers. Consider them for comparative context: