Key result
Exercise-induced T-wave alternans best discriminates VT/VF risk at lower heart rates.
Why the study?
Does the predictive power of exercise-induced T-wave alternans for the occurrence of ventricular arrhythmias depend on heart rate in heart failure patients with an ICD?
Case-Control (n=248)
Automatic TWA identification performed by individuals blinded to outcomes
No
Does the predictive power of exercise-induced T-wave alternans for the occurrence of ventricular arrhythmias depend on heart rate in heart failure patients with an ICD?
Answers are grounded in this paper and cite their sources.
Exercise-induced T-wave alternans has higher predictive power for ventricular arrhythmias at lower heart rates (80 bpm) rather than high heart rates (120 bpm), and the rate of change of TWA with heart rate (TWAAratio) is an independent risk predictor comparable in accuracy to LVEF.
BACKGROUND: T-wave alternans (TWA) is a noninvasive index of risk for the occurrence of ventricular arrhythmias. It is known that TWA amplitude (TWAA) increases with heart rate (HR) but how the TWA predictive power varies with HR remains unknown. Thus, the aim of this study was to evaluate the dependency of exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias from HR. METHODS: TWA was identified using our HR adaptive match filter in exercise ECGs from 248 patients with implanted cardiac defibrillator (ICD), of which 72 developed ventricular tachycardia and/or fibrillation during the 4 year follow-up (ICD_Cases) and 176 did not (ICD_Controls). TWA predictive power was evaluated at HRs from 80 to 120 bpm by computing the area under the receiver operating characteristic curve (AUC) obtained using the maximum TWAA (maxTWAA) and the TWAA ratio (TWAAratio; i.e., the ratio between TWAA at a specific HR and at 80 bpm). RESULTS: TWAA increased with HR. At 80 bpm maxTWAA was lower than at 120 bpm in both ICD_Cases (22 μV vs 41 μV; P < 10(-2) ) and ICD_ Controls (16 μV vs 36 μV; P < 10(-4) ). However, only at 80 bpm ICD_Cases showed significantly higher maxTWAA than ICD_Controls (AUC = 0.6486; P = 0.0080). TWAAratio was higher in ICD_Controls than ICD_Cases for all HR but 120 bpm, and its predictive power was maximum at 115 bpm (AUC = 0.6914; P < 0.05). CONCLUSIONS: Exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias, quantified using both maxTWAA and TWAAratio, was higher at low rather than at high HR.
No takes yet. Share an insight, caveat, or question.
Burattini et al. (2014) conducted a case-control in Heart failure with implanted cardiac defibrillator (ICD) for primary prevention (LVEF <35%) (n=248). Exercise-induced T-wave alternans (maxTWAA and TWAAratio) across heart rates 80 to 120 bpm vs. ICD Controls (patients without ventricular tachycardia or fibrillation during follow-up) was evaluated on Predictive power for occurrence of ventricular tachycardia and/or ventricular fibrillation (VT/VF) quantified by maximum T-wave alternans amplitude (maxTWAA) at 80 bpm (AUC 0.6486, p=0.0080). Exercise-induced T-wave alternans discriminated VT/VF cases from controls better at lower heart rates.
Synapse has enriched 10 related papers. Consider them for comparative context: