Prothrombin complex concentrate resulted in a lower posttreatment INR (1.32 vs 2.30) and significantly improved complete reversal and reversal time compared to FFP and vitamin K (p < 0.001).
Cohort
No
Does prothrombin complex concentrate improve complete reversal and reversal time in anticoagulated patients with intracranial haemorrhage requiring urgent neurosurgical intervention compared to fresh frozen plasma and vitamin K?
Prothrombin complex concentrate provides rapid and effective reversal of oral anticoagulation in life-threatening neurosurgical emergencies compared to fresh frozen plasma and vitamin K.
Absolute Event Rate: 1.32% vs 2.3%
p-value: p=< 0.001
The incidence of spontaneous intracranial haemorrhage has increased markedly in line with the increased use of oral anticoagulant agents. Recent guidelines for reversal of this acquired coagulation defect in an emergency have been established, but they are not adhered to in all centres. Our unit is referred between 20 and 60 patients per year (1994-1999) who are anticoagulated and require urgent neurosurgical intervention. In order to investigate this, we performed a prospective study using prothrombin complex concentrate (PCC). PCC was given to the first six patients with intracranial haemorrhage admitted to the neurosurgical unit requiring urgent correction of anticoagulation (Group 1) and compared with patients receiving standard treatment with fresh frozen plasma and vitamin K (Group 2). Mean International Normalised Ratios of Group 1 were 4.86 pretreatment and 1.32 posttreatment, and of Group 2 were 5.32 and 2.30, respectively. Results for complete reversal and reversal time were significant for PCC with p < 0.001. We recommend PCC for rapid and effective reversal of warfarin in life-threatening neurosurgical emergencies.
G. Dolan M. Cartmill (Sat,) conducted a cohort in Intracranial haemorrhage requiring urgent correction of anticoagulation. Prothrombin complex concentrate vs. Fresh frozen plasma and vitamin K was evaluated on Posttreatment International Normalised Ratio (INR) (p=< 0.001). Prothrombin complex concentrate resulted in a lower posttreatment INR (1.32 vs 2.30) and significantly improved complete reversal and reversal time compared to FFP and vitamin K (p < 0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: