Key result
Preoperative RV end-diastolic volume <147 ml/m2 identified patients with a shorter time to valve replacement (11.0 vs 30.1 years; P=0.03) who showed predictable intraoperative functional recovery.
Why the study?
Timing of pulmonary valve replacement (PVR) after tetralogy of Fallot repair is controversial, and whether a relationship exists between PVR timing and early functional recovery remains uncertain.
Does the timing of pulmonary valve replacement based on preoperative RV end-diastolic volume affect early intraoperative functional recovery in patients with repaired tetralogy of Fallot?
Observational (n=12)
Does the timing of pulmonary valve replacement based on preoperative RV end-diastolic volume affect early intraoperative functional recovery in patients with repaired tetralogy of Fallot?
Intraoperative video kinematic evaluation suggests that functional recovery after pulmonary valve replacement in tetralogy of Fallot is more predictable when performed before RV end-diastolic volume exceeds 147 ml/m2.
Answers are grounded in this paper and cite their sources.
Supports reevaluating 160 ml/m² RVEDVi threshold for PVR; hypothesis-generating for kinematic RV assessment in TOF.
OBJECTIVES: Indications for and timing of pulmonary valve replacement (PVR) after tetralogy of Fallot repair are controversial. Among magnetic resonance imaging indices proposed to time valve replacement, a right ventricular (RV) end-diastolic volume index greater than 160 ml/m2 is often used. Recent evidence suggests that this value may still identify patients with irreversible RV dysfunction, thus hindering recovery. Our goal was to define, using intraoperative video kinematic evaluation, whether a relationship exists between timing of PVR and early functional recovery after surgery. METHODS: Between November 2016 and November 2018, a total of 12 consecutive patients aged 27.1 ± 19.1 years underwent PVR on average 22.2 ± 13.3 years after tetralogy of Fallot repair. Mean RV end-diastolic volume evident on the magnetic resonance images was 136.9 ± 35.7 ml/m2. Intraoperative cardiac kinematics were assessed by video kinematic evaluation via a high-speed camera acquiring videos at 200 fps before and after valve replacement. RESULTS: Patients presenting with RV end-diastolic volume <147 ml/m2 were significantly younger (11.2 ± 5.0 vs 38.4 ± 17.0; P = 0.005) and had a shorter time interval to valve replacement (11.0 ± 5.2 vs 30.1 ± 11.3; P = 0.03). The entire population showed a moderate correlation among energy expenditure, cardiac fatigue, perimeter of contraction and preoperative RV end-diastolic volume index. Both groups showed a reduction in all kinematic parameters after PVR, but those with end-diastolic volume >147 ml/m2 showed an unpredictable outcome. CONCLUSIONS: Video kinematic evaluation provides insight into intraoperative RV recovery in patients with tetralogy of Fallot undergoing PVR. Accordingly, functional recovery can be expected in patients with preoperative end-diastolic volume <147 ml/m2.
No takes yet. Share an insight, caveat, or question.
Rozzi et al. (2021) conducted an observational in Tetralogy of Fallot (n=12). Preoperative RV end-diastolic volume <147 ml/m2 vs. Preoperative RV end-diastolic volume >147 ml/m2 was evaluated on Intraoperative RV functional recovery (kinematic parameters). Preoperative RV end-diastolic volume <147 ml/m2 identified patients with a shorter time to valve replacement (11.0 vs 30.1 years; P=0.03) who showed predictable intraoperative functional recovery.
Synapse has enriched 10 related papers. Consider them for comparative context: