Key result
The indirect Fick method for calculating cardiac output showed high correlation with the PiCCO method in hemodynamically unstable patients with sepsis.
Why the study?
Cardiac output is critical in managing critically ill patients, but existing invasive and non-invasive assessment methods have distinct drawbacks, leaving no ideal method.
Does cardiac output calculated by the indirect Fick method correlate with the PiCCO method in hemodynamically unstable patients with sepsis?
Observational (n=3)
No
Does cardiac output calculated by the indirect Fick method correlate with the PiCCO method in hemodynamically unstable patients with sepsis?
The indirect Fick method shows high correlation with the PiCCO method for measuring cardiac output in septic patients, offering a potential alternative in resource-limited settings.
Answers are grounded in this paper and cite their sources.
Supports indirect Fick as potential alternative to PiCCO in septic shock; leaves open prospective validation before clinical adoption.
Background. Cardiac output (CO) is an indicator in the treatment of patients in critical condition. There are many methods for assessment CO, both invasive and non-invasive. All methods have their advantages and disadvantages, but the perfect method has not been found. Aim. Comparison of the assessment of СО by the PiCCO method and Fick's indirect method. Materials and methods. A pilot observational study was conducted on the basis of O.O. Shalimov National institute of surgery and transplantology. 12 results of CO measurement by the PiCCO method and CO calculation by the indirect Fick method in three patients were analysed. We analysed the results using the Excel descriptive statistics method, and also evaluated correlation in Excel. Results. The correlation coefficient of CO, estimated by more methods, r = 0.96, which showed the result of a high correlation of results. However, absolute values varied from 1.7 % to 19.9 %, which can be an acceptable error in conditions of limited resources. Correlation coefficient of cardiac index r = 0.98, and stroke volume index r = 0.98, which is also about high connection. Stroke volume correlation coefficient r = 0.64, which has a moderate connection. Variation in cardiac index and stroke volume vere within wide ranges (from 0.25 % to 27 % and from 1 % to 33 %, respectively). Conclusion. Cardiac output calculated by Fick's method in patients with sepsis and septic shock can be an alternative to CO determined by the PiCCO method in the case of limited resources.
No takes yet. Share an insight, caveat, or question.
SYDYUK et al. (2023) conducted an observational in Sepsis (n=3). Indirect Fick method vs. PiCCO method was evaluated on Correlation of cardiac output assessment (r = 0.96). The indirect Fick method for calculating cardiac output showed high correlation with the PiCCO method in hemodynamically unstable patients with sepsis.