Key result
Cardiac computed tomography successfully distinguished thrombus from pannus in a patient with an elevated prosthetic valve gradient, leading to complete resolution with oral anticoagulants.
Why the study?
Differentiating between thrombus formation and pannus overgrowth as the cause of bioprosthetic valve dysfunction can be challenging with echocardiography alone.
Case Report (n=1)
Cardiac computed tomography is valuable for distinguishing bioprosthetic valve thrombosis from pannus overgrowth, enabling successful treatment with oral anticoagulation.
Echocardiographic differentiation of bioprosthetic valve thrombus from pannus remains challenging; leaves open optimal imaging strategies for confirmation.
Bioprosthetic valve thrombosis was previously considered to be a relatively rare complication of surgical or transcatheter bioprosthetic valve replacement. Although echocardiograms can reliably show the characteristic findings of prosthetic valve stenosis, differentiating between thrombus formation and pannus overgrowth as the underlying cause of prosthetic valve dysfunction can be challenging. We present the case of a 75-year-old man who underwent transthoracic Doppler echocardiography in the presence of an elevated valvular gradient 2 years after his aortic valve had been surgically replaced with a bioprosthesis. The echocardiographic findings suggested prosthetic valve stenosis. Cardiac computed tomography, performed to distinguish between thrombus formation and pannus overgrowth, revealed hypoattenuated leaflet thickening and reduced leaflet mobility, which suggested thrombus. After the patient took oral anticoagulants for 3 months, images showed complete resolution of the previous abnormalities, thus confirming the diagnosis of bioprosthetic valve thrombosis. We found cardiac computed tomography valuable when evaluating our patient who had an elevated prosthetic valve gradient.
No takes yet. Share an insight, caveat, or question.
Kealhofer et al. (2019) conducted a case report in Bioprosthetic valve thrombosis (n=1). Cardiac computed tomography was evaluated. Cardiac computed tomography successfully distinguished thrombus from pannus in a patient with an elevated prosthetic valve gradient, leading to complete resolution with oral anticoagulants.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: