Key result
A doubling of serum NT-proBNP was independently associated with a 1.83% decrease in left ventricular ejection fraction (95% CI -2.63 to -1.03; P<0.0001) and worsening of other echo parameters.
Why the study?
To further elucidate how NT-proBNP, hs-TnT, and CRP relate to clinical outcome, the study evaluated the relationship between serial simultaneous measurements of echocardiographic parameters and these biomarkers in chronic heart failure.
Do longitudinal changes in NT-proBNP, hs-TnT, and CRP correlate with dynamics of echocardiographic parameters in patients with chronic heart failure?
Cohort (n=117)
Do longitudinal changes in NT-proBNP, hs-TnT, and CRP correlate with dynamics of echocardiographic parameters in patients with chronic heart failure?
Mean Difference: -1.83 (95% CI -2.63–-1.03)
p-value: p=< 0.0001
Serial measurements of NT-proBNP independently reflect changes in echocardiographic parameters of systolic function, filling pressures, and chamber dimensions in chronic heart failure patients.
AIMS: To further elucidate the nature of the association between N-terminal pro-B type natriuretic peptide (NT-proBNP), high-sensitivity cardiac troponin T (hs-TnT), C-reactive protein (CRP), and clinical outcome, we examined the relationship between serial simultaneous measurements of echocardiographic parameters and these biomarkers in chronic heart failure (CHF) patients. METHODS AND RESULTS: In 117 CHF patients with ejection fraction ≤50%, NT-proBNP, hs-TnT, and CRP were measured simultaneously with echocardiographic evaluation at 6-month intervals until the end of 30 months follow-up or until an adverse clinical event occurred. Linear mixed effects models were used for data-analysis. Median follow-up was 2.2 years (interquartile range 1.5-2.6). We performed up to six follow-up evaluations with 55% of patients having at least three evaluations performed. A model containing all three biomarkers revealed that doubling of NT-proBNP was associated with a decrease in left ventricular ejection fraction by 1.83 (95% confidence interval -2.63 to -1.03)%, P < 0.0001; relative increase in mitral E/e' ratio by 12 (6-18)%, P < 0.0001; relative increase in mitral E/A ratio by 16 (9-23)%, P < 0.0001; decrease in tricuspid annular plane systolic excursion by 0.66 (-1.27 to -0.05) mm, P = 0.03; rise in tricuspid regurgitation peak systolic gradient by 2.74 (1.43-4.05) mmHg, P = 0.001; and increase in left ventricular and atrial dimensions, P < 0.05. Hs-TnT and CRP showed significant associations with some echocardiographic parameters after adjustment for clinical covariates, but after adjustment for the other biomarkers the associations were not significant. CONCLUSION: Serum NT-proBNP independently reflects changes in echocardiographic parameters of systolic function, left ventricular filling pressures, estimated pulmonary pressure, and chamber dimensions. Our results support further studies on NT-proBNP as a surrogate marker for haemodynamic congestion and herewith support its potential value for therapy guidance.
No takes yet. Share an insight, caveat, or question.
Klimczak‐Tomaniak et al. (2019) conducted a cohort in chronic heart failure (CHF) (n=117). NT-proBNP was evaluated on change in left ventricular ejection fraction per doubling of NT-proBNP (decrease by 1.83%, 95% CI -2.63 to -1.03, p=< 0.0001). A doubling of serum NT-proBNP was independently associated with a 1.83% decrease in left ventricular ejection fraction (95% CI -2.63 to -1.03; P<0.0001) and worsening of other echo parameters.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: