Key result
Br-Spine and RLAD-Spine radiographic measurements were less sensitive than RLAD in detecting left atrial enlargement in dogs.
Why the study?
To evaluate the clinical usefulness of two new radiographic measurements (Br-Spine and RLAD-Spine) compared to RLAD for detecting and quantifying left atrial enlargement against echocardiographic LA/Ao ratio.
Do Br-Spine and RLAD-Spine radiographic measurements accurately detect left atrial enlargement in dogs with mitral insufficiency compared to RLAD?
Cross-Sectional (n=50)
Observer blinded to patient details
Do Br-Spine and RLAD-Spine radiographic measurements accurately detect left atrial enlargement in dogs with mitral insufficiency compared to RLAD?
Br-Spine and RLAD-Spine are less sensitive than RLAD for detecting left atrial enlargement in dogs and are not recommended as alternatives.
Answers are grounded in this paper and cite their sources.
New heart-to-spine measures were less sensitive than RLAD for LAE detection; leaves open whether refined radiographic indices can substitute echocardiography.
BACKGROUND: Radiography is useful to determine left atrial (LA) size when echocardiography is not available. Recently, the authors have described Radiographic Left Atrial Dimension (RLAD) as a new radiographic measurement to assess LA size. The objective of this study was to assess the clinical usefulness of 2 new radiographic measurements to detect and quantify left atrial enlargement (LAE) compared to RLAD and using left atrium to aortic root (LA/Ao) ratio as gold standard. These new measurements, bronchus-to-spine (Br-Spine) and RLAD-to-spine (RLAD-Spine) may be more precise in cases were LA boundaries are not well defined. Fifty dogs, 25 with and 25 without LAE were recruited. Reference LA/Ao ratio was assessed by 2D echocardiography and LAE was considered if LA/Ao > 1.6. Br-spine was measured as a straight vertical line from the main stem bronchus to the ventral border of the vertebra situated immediately dorsal to the heart base. RLAD-Spine was measured from RLAD endpoint perpendicularly to spine. The correlation of RLAD, Br-Spine and RLAD-Spine methods with LA/Ao and their sensitivity and specificity for detecting LAE were calculated. Receiver Operating Characteristic (ROC) curves were used to estimate the optimal cut-off for each method. Sensitivity at the optimal cut-off values for detecting LAE were 32.0, 64.0 and 96.0%, respectively. Specificity was 96.0% in all cases. CONCLUSION: Br-Spine and RLAD-Spine were less sensitive radiographic measurements than RLAD in detecting LAE in dogs. Both Br-Spine and RLAD-Spine may not be good alternatives to RLAD.
No takes yet. Share an insight, caveat, or question.
Salguero et al. (2019) conducted a cross-sectional in Mitral insufficiency and left atrial enlargement (n=50). Br-Spine and RLAD-Spine radiographic measurements vs. RLAD measurement was evaluated on Sensitivity for detecting left atrial enlargement. Br-Spine and RLAD-Spine radiographic measurements were less sensitive than RLAD in detecting left atrial enlargement in dogs.
Synapse has enriched 10 related papers. Consider them for comparative context: