Key result
Manual analysis of continuous ECG monitoring (hCEM) detected significantly more new atrial fibrillation cases than semiautomated analysis (13.8% vs 10.2%, p=0.003) in ischemic stroke patients.
Why the study?
Does prolonged continuous ECG monitoring analyzed manually or semiautomatically improve atrial fibrillation detection compared to 24-hour Holter ECG in ischemic stroke patients?
Cohort (n=362)
Does prolonged continuous ECG monitoring analyzed manually or semiautomatically improve atrial fibrillation detection compared to 24-hour Holter ECG in ischemic stroke patients?
Prolonged continuous ECG monitoring with manual Holter analysis provides the highest atrial fibrillation detection rate in ischemic stroke patients compared to semiautomated analysis or standard 24-hour Holter.
May warrant manual ECG review to maximize post-stroke AF detection; leaves open outcome impact and need for trials.
BACKGROUND: Tracking down atrial fibrillation (AF) in the stroke unit is a relevant challenge for the prevention of recurrent AF-related stroke. The optimal terms of use of continuous ECG monitoring (CEM) are unknown. We compared 24-hour routine Holter ECG with two different CEM analysis strategies for AF detection. METHODS: We prospectively enrolled consecutive ischemic stroke patients. All AF-naïve patients received CEM during hospitalization. Two methods for reading CEM data were compared: manual analysis using the Holter function (hCEM) and semiautomated analysis using software (aCEM). The McNemar test was used to compare AF detection rates. RESULTS: Of the 362 patients included, 58 (16.0%) were non-AF-naïve patients and 304 were AF-naïve patients. AF-Naïve patients underwent CEM with a median duration of 5.3 days (3.4-9.7). We detected 22 new AF cases (7.2%) with first-24-hour hCEM, 31 (10.2%) with aCEM, and 42 (13.8%) with hCEM. hCEM and aCEM both significantly increased the AF detection rate compared to first-24-hour hCEM. hCEM detected more new AF cases than aCEM (+3.6%, p = 0.003). CONCLUSIONS: In stroke patients, early and prolonged aCEM and hCEM both increase the AF detection rate compared to first-24-hour hCEM. hCEM gives the best AF detection rate. We suggest that in aCEM, detection based only on the ventricular rhythm analysis explains its lower specificity and sensitivity.
No takes yet. Share an insight, caveat, or question.
Suissa et al. (2014) conducted a cohort in Ischemic stroke (n=362). Manual analysis using Holter function (hCEM) vs. Semiautomated analysis (aCEM) was evaluated on Atrial fibrillation detection rate (+3.6%, p=0.003). Manual analysis of continuous ECG monitoring (hCEM) detected significantly more new atrial fibrillation cases than semiautomated analysis (13.8% vs 10.2%, p=0.003) in ischemic stroke patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: