Key result
Electronic monitoring and pharmacy refill records showed very little agreement in measuring antihypertensive medication compliance, yielding a Cohen's kappa coefficient of 0.005.
Why the study?
Does electronic monitoring agree with pharmacy refill records for measuring antihypertensive medication compliance in patients with uncontrolled hypertension?
Observational (n=161)
Yes
Does electronic monitoring agree with pharmacy refill records for measuring antihypertensive medication compliance in patients with uncontrolled hypertension?
Answers are grounded in this paper and cite their sources.
BACKGROUND: Poor compliance with antihypertensive medication is assumed to be an important reason for unsatisfactory control of blood pressure. Poor compliance is difficult to detect. Each method of measuring compliance has its own strengths and weaknesses. The aim of the present study was to compare patient compliance with antihypertensive drugs as measured by two methods, electronic monitoring versus refill compliance. METHODS: 161 patients with a diagnosis of hypertension for at least a year prior to inclusion, and inadequate blood pressure control (systolic blood pressure > or = 160 mmHg and/or diastolic blood pressure > or = 95 mmHg) despite the use of antihypertensive drugs, were included. Patients' pharmacy records from 12 months prior to inclusion were obtained. Refill compliance was calculated as the number of days for which the pills were prescribed divided by the total number of days in this period. After inclusion compliance was measured with an electronic monitor that records time and date of each opening of the pillbox. Agreement between both compliance measures was calculated using Spearman's correlation coefficient and Cohen's kappa coefficient. RESULTS: There was very little agreement between the two measures. Whereas refill compliance showed a large range of values, compliance as measured by electronic monitoring was high in almost all patients with estimates between 90% and 100%. Cohen's kappa coefficient was 0.005. CONCLUSION: While electronic monitoring is often considered to be the gold standard for compliance measurements, our results suggest that a short-term electronic monitoring period with the patient being aware of electronic monitoring is probably insufficient to obtain valid compliance data. We conclude that there is a strong need for more studies that explore the effect of electronic monitoring on patient's compliance.
No takes yet. Share an insight, caveat, or question.
Wetzels et al. (2006) conducted an observational in Hypertension (n=161). Electronic monitoring vs. Pharmacy refill records was evaluated on Agreement between electronic monitoring and refill compliance (Spearman's correlation -0.02, 95% CI -0.18-0.15). Electronic monitoring and pharmacy refill records showed very little agreement in measuring antihypertensive medication compliance, yielding a Cohen's kappa coefficient of 0.005.
Synapse has enriched 10 related papers. Consider them for comparative context: