Key result
The high sensitivity troponin T assay yielded significantly more positive results than the 4th generation assay (50% vs 22%, P<0.001), often in patients with diagnoses other than AMI.
Why the study?
Does high sensitivity troponin T assay increase the proportion of positive results compared to 4th generation assay in patients tested for troponin?
Observational (n=161)
Single-blind
Does high sensitivity troponin T assay increase the proportion of positive results compared to 4th generation assay in patients tested for troponin?
Absolute Event Rate: 50% vs 22%
p-value: p=< 0.001
The use of high-sensitivity troponin T assays more than doubles the rate of positive results compared to 4th generation assays, often in patients without acute myocardial infarction, which may lead to unnecessary downstream testing.
hsTnT doubles troponin-positive rate vs cTnT; leaves open whether added detections improve 90-day risk stratification in ED patients.
BACKGROUND: High sensitivity troponin T (hsTnT) detects lower levels of troponin T with greater precision than the 4th generation (cTnT) assay. However, the clinical implications of this are uncertain. OBJECTIVES: Primary: Describe the proportion of patients who test 'positive' with hsTnT but negative with cTnT. Secondary: Determine proportion in each group with an adverse event (representation, AMI or died) within 90 days of the index test. METHOD: 161 patients samples were tested with cTnT and hsTNT assays. McNemar's test was used to compare paired samples. Electronic medical records were reviewed, with discharge diagnosis and 90 day outcomes determined blind to hsTnT results. Patients were then classified as 'TnT negative' (hsTnT was <0.014 mcg/mL), 'new positive' (hsTnT was ≥ 0.014 mcg/mL and cTnT <0.03 mcg/mL) and 'TnT positive' (cTNT was ≥ 0.03 mcg/mL). RESULTS: Positive results more than doubled with the hsTnT assay (50% vs 22%, P < 0.001). 81 patients were 'TnT negative', 44 were 'new positive' and 36 'cTnT positive'. The discharge diagnosis for 'new positives' was AMI in 4 (9%), other cardiac in 13 (30%) and non-cardiac in 27 (61%). At 90 days adverse events occurred in 30%, 54% and 50% of the groups respectively. There were no late cases of AMI or cardiovascular death in 'new positive' patients. CONCLUSION: Many patients with diagnoses other than AMI will have hsTNT above the reference level. Indiscriminate testing with hsTnT might lead to more patients requiring serial troponin testing and/or invasive further tests, which will have process and resource implications for EDs and health services.
No takes yet. Share an insight, caveat, or question.
Jairam et al. (2011) conducted an observational in Patients undergoing troponin testing (n=161). High sensitivity troponin T (hsTnT) assay vs. 4th generation troponin T (cTnT) assay was evaluated on Positive troponin test result (p=< 0.001). The high sensitivity troponin T assay yielded significantly more positive results than the 4th generation assay (50% vs 22%, P<0.001), often in patients with diagnoses other than AMI.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: