Key result
Cardiointervalography parameters indicated a failure of adaptation and mismatch of regulatory systems in severe and extremely severe newborns compared with healthy controls.
Why the study?
Does cardiointervalography objectively estimate the severity of condition in newborns?
Observational (n=59)
Does cardiointervalography objectively estimate the severity of condition in newborns?
Cardiointervalography may be a useful tool to objectively estimate and monitor the severity of condition in critically ill newborns.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for cardiointervalography in assessing newborn severity; prospective validation needed before clinical adoption.
There were examined 15 full-term and 14 preterm newborns in the intensive care unit, whose state was estimated as severe and extremely severe. The control group consisted of 30 newborns with uncomplicated course of the early adaptation. The results of the study showed that the parameters of cardiointervalography recording and their dynamics in the diseased newborns compared with healthy newborns indicate the failure of adaptation and mismatch of regulatory systems. In our opinion, the implementation of cardiointervalography in newborns allows to objectively estimate the severity of newborns' condition and allows to monitor the dynamics of their state.
No takes yet. Share an insight, caveat, or question.
Malyuga et al. (2018) conducted an observational in Severe and extremely severe state in newborns (n=59). Cardiointervalography vs. Healthy newborns was evaluated on Parameters of cardiointervalography recording and their dynamics. Cardiointervalography parameters indicated a failure of adaptation and mismatch of regulatory systems in severe and extremely severe newborns compared with healthy controls.
Synapse has enriched 10 related papers. Consider them for comparative context: