Why the study?
Does venous beta-adrenergic sensitivity correlate with arterial beta-adrenergic sensitivity in healthy normotensive men?
Does venous beta-adrenergic sensitivity correlate with arterial beta-adrenergic sensitivity in healthy normotensive men?
Venous and arterial beta-adrenergic responses are regulated differently and do not correlate, indicating that venous responses cannot substitute for arterial responses in studies of vascular beta-adrenoceptor sensitivity.
Venous measures should not substitute for arterial beta-adrenergic sensitivity; hypothesis-generating for differential regulation and requires prospective confirmation.
The regulation of vascular beta-adrenoceptor responses in humans has been studied in vivo in both arteries and veins. Because venous responses can be studied less invasively than arterial responses, they are an attractive substitute for the measurement of arterial responses, provided that venous responses are representative of responses in resistance arteries. However, although venous, particularly hand vein response, has been extensively studied, arterial and venous beta-adrenergic sensitivities, in the same individuals, have not been compared. Measures of venous and arterial beta-adrenergic sensitivities were compared in 10 healthy normotensive subjects. Forearm blood flow, after administration of increasing doses of isoproterenol into the brachial artery, was measured by strain-gauge plethysmography and was used for determination of arterial beta-adrenoceptor sensitivity, expressed as the IP500 (the dose of isoproterenol resulting in a fivefold [500%] increase in baseline forearm blood flow). Venous sensitivity to isoproterenol, expressed as the IP15 (the dose of isoproterenol resulting in 15% venodilation), was measured in a dorsal hand vein using the linear variable differential transformer. Administration of isoproterenol into the hand vein and brachial artery resulted in venodilation and increased forearm blood flow, respectively. However, there was no correlation between the measures of venous (log IP15) and arterial (log IP500) measures of vascular beta-adrenergic sensitivity (r = -.12, P = .74). We conclude that since arterial and venous sensitivities to isoproterenol in healthy white men did not correlate, venous and arterial beta-adrenergic responses are regulated differently and that studies examining vascular beta-adrenoceptor sensitivity would most appropriately be performed in a vessel representative of the vascular bed of interest.
No takes yet. Share an insight, caveat, or question.
Stein et al. (1997) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: