Answers are grounded in this paper and cite their sources.
Even under the same implantation conditions, e.g., 50-keV 11B+ ions implanted through 1100-Å gate oxides on 4-Ω cm silicon substrates, the threshold voltage shift of n -channel MOS transistors is ∼55% of the shift of p -channel specimens, and deviation from linear dose dependence is observed for the n channel above a dose of 6×1011/cm2, while for a p -channel case the threshold voltage shift depends linearly on the net dose in silicon at least up to 1×1012/cm2. These results are discussed and explained with a calculated dose dependence that accounts for the large decrease of the maximum width of the depletion layer with increasing dose for acceptor-implanted n -channel specimens.
No takes yet. Share an insight, caveat, or question.
Kamoshida et al. (1974) studied this question.