Key result
Low patient activity (<2 hours/day) was associated with a significantly higher level of arrhythmic episodes (P<0.05) and appropriate shock or ATP (P<0.001) compared to higher activity levels.
Why the study?
Although ICDs reduce mortality in heart failure patients with reduced left ventricle function, arrhythmic episodes increase mortality, and whether low patient activity predicts arrhythmic events remains unknown.
Does low patient activity detected by ICD predict arrhythmic events in heart failure patients with primary prevention ICDs?
Observational (n=206)
Does low patient activity detected by ICD predict arrhythmic events in heart failure patients with primary prevention ICDs?
p-value: p=<0.05
Low daily physical activity (<2 hours) detected by ICDs is associated with a significantly higher risk of arrhythmic episodes and appropriate device therapies in heart failure patients.
Supports activity monitoring as a potential risk marker in ICD patients; hypothesis-generating for prospective trials on activity modification.
BACKGROUND: Although implantable cardioverter-defibrillator (ICD) reduces mortality in heart failure patients with reduced left ventricle function, arrhythmic episodes are related with increased mortality. Aim: The aim of this study was to investigate whether low patient activity predicts arrhythmic events in the heart failure patients with primary prevention ICD. METHODS: We examined 206 heart Failure (HF) patients (mean age: 61.3 ± 10.9 years, 77.7% male) with primary prevention implanted ICD who referred to our outpatient clinic for pacemaker control. After pacemaker (PM) controls, the overall study group was categorized into three distinct subgroups: Activity less than 2 h, activity 2-4 h, and activity 4-8 h in a day. RESULTS: Activity less than 2 h had a substantially higher level of arrhythmic episodes in comparison to other groups (P < 0.05). In addition, appropriate shock or ATP (antitachycardia pacing) was detected higher in patients whose activity was less than 2 h in a day than other groups (P < 0.001). CONCLUSIONS: Detected low patient activity in ICD control may be a predictor of arrhythmic episodes and appropriate therapies. Increasing physical activity may potentially protect these patients from unwanted events.
No takes yet. Share an insight, caveat, or question.
Ucar et al. (2020) conducted an observational in Heart failure with primary prevention ICD (n=206). Low patient activity (<2 hours/day) vs. Higher patient activity (2-4 hours and 4-8 hours/day) was evaluated on Arrhythmic episodes (p=<0.05). Low patient activity (<2 hours/day) was associated with a significantly higher level of arrhythmic episodes (P<0.05) and appropriate shock or ATP (P<0.001) compared to higher activity levels.