Accounting for EGTA purity, hydration, ionic strength, and pH is necessary for accurate calculation of calcium ion concentrations in physiological solutions.
Answers are grounded in this paper and cite their sources.
Requires EGTA corrections for accurate Ca2+ calculations; extends prior buffer methods in physiological research.
Results are presented for the purity of three commercial brands of the Ca chelator EGTA [ethyleneglycol-bis(beta-aminoethylether)-N,N'-tetraacetic acid] as determined with pH-metric and oxalate precipitation methods and other techniques. The effect that the observed degree of hydration (2-4%) has on calculated values for [Ca2+] in Ca-EGTA solutions is described with reference to a theoretical dose-response relationship. In addition to the corrections for purity, the adjustments necessary to allow for ionic strength and the correction of pH readings to yield true [H+] activity or concentration values are described. These several corrections result in both a shift and a shape change for the dose-response curve compared with the curve calculated without these corrective procedures. Some authors have already taken some of these aspects into account, but this has not generally been made clear in the literature heretofore. The points raised may help to account for the wide variation of reported [Ca2+] ranges for Ca-sensitive cellular processes.
No takes yet. Share an insight, caveat, or question.
Miller et al. (1984) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: