Key result
Mechanical stretch reduced cardiac conduction velocity from 0.42 m/s to 0.36 m/s and significantly altered spiral wave dynamics through stress-assisted diffusion and stretch-activated currents.
Why the study?
The role of mechanical stress in modifying the conductivity properties of cardiac tissue and its impact in computational models for cardiac electromechanics remained to be numerically investigated.
Absolute Event Rate: 0.36% vs 0.42%
Mechanical deformation significantly alters cardiac conduction velocity and wave dynamics through stress-assisted diffusion and stretch-activated currents.
We numerically investigate the role of mechanical stress in modifying the conductivity properties of cardiac tissue, and also assess the impact of these effects in the solutions generated by computational models for cardiac electromechanics. We follow the recent theoretical framework from Cherubini et al. (2017), proposed in the context of general reaction-diffusion-mechanics systems emerging from multiphysics continuum mechanics and finite elasticity. In the present study, the adapted models are compared against preliminary experimental data of pig right ventricle fluorescence optical mapping. These data contribute to the characterization of the observed inhomogeneity and anisotropy properties that result from mechanical deformation. Our novel approach simultaneously incorporates two mechanisms for mechano-electric feedback (MEF): stretch-activated currents (SAC) and stress-assisted diffusion (SAD); and we also identify their influence into the nonlinear spatiotemporal dynamics. It is found that (i) only specific combinations of the two MEF effects allow proper conduction velocity measurement; (ii) expected heterogeneities and anisotropies are obtained via the novel stress-assisted diffusion mechanisms; (iii) spiral wave meandering and drifting is highly mediated by the applied mechanical loading. We provide an analysis of the intrinsic structure of the nonlinear coupling mechanisms using computational tests conducted with finite element methods. In particular, we compare static and dynamic deformation regimes in the onset of cardiac arrhythmias and address other potential biomedical applications.
No takes yet. Share an insight, caveat, or question.
Loppini et al. (2018) studied Cardiac arrhythmias. Mechanical stretch vs. No stretch (free edges) was evaluated on Conduction velocity (CV). Mechanical stretch reduced cardiac conduction velocity from 0.42 m/s to 0.36 m/s and significantly altered spiral wave dynamics through stress-assisted diffusion and stretch-activated currents.