Why the study?
Evidence evaluating carbon dioxide as an alternative to iodinated contrast media for venous angiography in cardiac implantable electronic device procedures was limited to one small study.
Does carbon dioxide venous angiography provide comparable vessel visualization to iodinated contrast media in patients undergoing CIED procedures?
Does carbon dioxide venous angiography provide comparable vessel visualization to iodinated contrast media in patients undergoing CIED procedures?
Carbon dioxide venography is a feasible and safe alternative to iodinated contrast media for venous visualization during CIED procedures, offering comparable imaging quality while potentially avoiding contrast-induced nephropathy.
Answers are grounded in this paper and cite their sources.
CO2 venography yields lower variability than ICM for subclavian assessment in CIED procedures; extends RCT evidence supporting its use as a contrast alternative.
Venography continues to be a valuable tool during cardiac implantable electronic device (CIED) procedures, particularly in complex scenarios like device upgrades or lead extractions, despite the widespread use of ultrasound-guided access.1–4 Carbon dioxide (CO₂) has emerged as a potential alternative to iodinated contrast media (ICM), especially in patients at risk for contrast-induced nephropathy (CIN) or with ICM allergies, though evidence evaluating its use in venous angiography in CIED procedures is limited to one small study.5 To address this gap, this study aimed to compare CO₂ and ICM venography in CIED-related interventions and assess the safety of CO₂. This prospective, single-centre randomized crossover study compared CO₂ and ICM venous angiography during CIED procedures. Patients presenting right-to-left shunt (evaluated via pre-procedural echocardiography with bubble test), pulmonary hypertension, lung failure, or known allergy to ICM were excluded. The sequence of imaging techniques was randomized. Carbon dioxide angiography was performed using an automated system, delivering a 50 mL CO₂ bolus at 300 mmHg, preceded by a 10 mL flush, and images were enhanced with digital subtraction angiography (DSA) and stacking techniques. Digital subtraction angiography subtracts pre- and post-contrast images to isolate contrast-enhanced structures, while stacking overlays multiple frames to improve image clarity. Two stacking tools were used: default stacking (DS) integrated in current X-ray system and a custom-made software (CS) approach, requiring image upload into a specific software (Figure 1, panel 1). Comparison of iodinated contrast media and carbon dioxide venography in CIED-related interventions. Two experienced radiology technicians, blind to the study, independently assessed image quality for multiple venous segments (e.g. axillary, subclavian; see Figure 1, panel 2). The primary endpoint was vessel visualization evaluated by patency visibility and optimal visualization, defined as a lumen-to-background contrast enabling measurement of vessel diameter and degree of stenosis for each modality [with/without stacking (WoS)]. The secondary endpoint was to evaluate the incidence of adverse events. All patients provided written informed consent, and the study was approved by the Institutional Review Boards and conducted following the Declaration of Helsinki. Continuous variables were summarized as mean ± standard deviation or median and interquartile range, based on their distribution. Group differences were assessed using the Student’s t-test. Inter-operator agreement and intra-method variability were assessed by comparing the standard deviation of measurement differences. Analyses were conducted using STATA (v.18.0, StataCorp LLC, College Station, USA). Among the 62 patients screened, two were excluded (one due to a patent foramen ovale with a right-to-left shunt and the other due to severe pulmonary hypertension). Sixty patients were included (76.7% male, mean age of 72.6 ± 13.1 years, and a mean creatinine 1.3 ± 0.7 mg/dL). Visibility rates, defined as the percentage of veins in which the patency can be determined, are reported in Figure 1, panel 2. The proportion of veins with optimal visualization is reported in Figure 1, panel 3. Inter-operator agreement for image quality classification (i.e. non-visible, patency visibility, optimal visualization) was good across all venous segments. Intra-method variability, measured by the standard deviation of differences between the two operators’ measurements, was lower with CO₂ than with ICM (ICM: 2.41; CO₂ WoS: 2.02; DS: 1.98; CS: 1.96). The reduction was statistically significant for both WoS (P = 0.03) and stacking techniques (DS: P = 0.02; CS: P = 0.01). Three venous stenoses > 75% were identified with both ICM and CO2, regardless of post-processing techniques: one in the axillary and two in the subclavian veins. Four patients (6.7%) experienced CIN, defined as a 25% relative increase or a 0.5 mg/dL absolute increase in serum creatinine. No acute adverse events were reported in either imaging group. This study compared ICM and CO₂ venography for evaluating major thoracic veins in CIED candidates. Carbon dioxide venography WoS visualized subclavian vein patency in over 90% of cases, with results comparable to ICM. Patency visualization of the axillary and innominate veins was slightly lower but remained above 80%. Carbon dioxide venography WoS proved suitable for CIED procedures, offering almost real-time imaging without the need for time-consuming post-processing. Stacking techniques further enhanced image quality in most venous districts, allowing for clearer delineation of vessel size and morphology. This may provide a significant advantage in complex cases where precise anatomical assessment is critical. These results are consistent with two smaller non-randomized studies that compared CO₂ venography with ICM venography outside the CIED context6,7 and are further supported by evidence from interventional procedures involving CO₂ upper limb venous system venography.8 Winters et al.5 previously evaluated CO₂ venography in 23 patients undergoing revision of existing pacemaker or ICD systems, though without ICM comparison. Additionally, Okubo et al.9 reported two successful cases of CO2 coronary sinus angiography in patients undergoing cardiac resynchronization therapy. Despite the challenges associated with DSA techniques and severe motion artefacts, instructing breath-hold to the patient enabled image acquisition sufficient for catheter guidance. Thanks to its unique properties, CO₂ enables safe, efficient delivery of large, undiluted boluses, enhancing the visualization of high-capacity central veins often sub-optimally assessed by ICM. This may be particularly valuable in CIED procedures, especially in complex cases requiring precise periprocedural planning for contralateral implantations. In this study, 6.7% of patients developed CIN despite guidelines prophylactic hydration. No CO₂-related adverse events were observed in this study. The most common CO₂-related complication reported in literature is brief injection-site pain, attributed to the explosive delivery of compressed gas; however, the use of an automated injection system in this study likely mitigated this and automated delivery minimizes the risk of air contamination, gas embolism, and intrapulmonary vapour lock.10 This study is limited by its single-centre design and moderate sample size, which may restrict the generalizability of the findings. A larger cohort and a parallel-group design would be necessary to more rigorously assess safety outcomes. Moreover, image interpretation was performed by two expert electrophysiology technicians, potentially introducing reviewer bias. Carbon dioxide venography represents a feasible and safe alternative to ICM in CIED procedures, with post-processing stacking software further enhancing image quality. Further studies are warranted to validate its broader clinical applications, such as coronary sinus imaging, identify patient populations that may benefit most, and evaluate its potential for reducing CIN. The data underlying this article will be shared on reasonable request to the corresponding author.
No takes yet. Share an insight, caveat, or question.
Spadotto et al. (2025) studied this question.