Why the study?
Does the clinical and echocardiographic response to CRT-D differ between patients enrolled in US versus non-US centers in the MADIT-CRT trial?
Does the clinical and echocardiographic response to CRT-D differ between patients enrolled in US versus non-US centers in the MADIT-CRT trial?
Despite differences in baseline characteristics and higher procedure-related complication rates in non-US centers, patients in US and non-US centers derived similar clinical and echocardiographic benefits from CRT-D in the MADIT-CRT trial.
Answers are grounded in this paper and cite their sources.
Consistent CRT-D benefits across US/non-US groups; extends MADIT-CRT generalizability but leaves real-world applicability open.
AIMS: We aimed to evaluate within the MADIT-CRT database whether different enrollment characteristics between US and non-US centres affected the clinical course of study patients. METHODS AND RESULTS: We evaluated differences in baseline characteristics, procedure-associated complications, clinical as well as echocardiographic response to cardiac resynchronization therapy with a defibrillator (CRT-D), between patients enrolled in 87 US centres (n = 1271) and 23 non-US centres (n = 549) in MADIT-CRT. Non-US patients displayed significant differences in baseline characteristics from US patients, including a higher frequency of left bundle branch block, a more advanced heart failure (HF) functional class >3 months prior to enrollment, and larger baseline cardiac volumes. Procedure-related complications occurred at a significantly higher frequency among patients enrolled in non-US centres (17%) than among those enrolled in US centres (10%; P < 0.001). During follow-up, CRT-D was associated with 42% (P = 0.003) and 38% (P < 0.001) reductions in the risk of HF or death in the two respective groups (P for the difference = 0.80), and with similar reductions in cardiac volumes (all P > 0.10). Subgroup analysis showed a more pronounced effect of CRT-D among women in the US group, including a significant 71% (P = 0.02) reduction in the risk of death, whereas CRT-D therapy was associated with a significant clinical benefit in men only in the non-US group. CONCLUSION: Patients enrolled in US and non-US centres in MADIT-CRT displayed significant differences in baseline clinical and echocardiographic characteristics and in the frequency of procedure-related complications, but experienced an overall similar clinical and echocardiographic response to CRT-D.
No takes yet. Share an insight, caveat, or question.
Buber et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: