Why the study?
Hypotensive events and drops in systolic blood pressure are frequent in acute heart failure, but whether they are associated with outcomes in patients treated with serelaxin remained unclear.
Do SBP-drops during hospitalization for acute heart failure worsen outcomes, and does serelaxin treatment modify this risk?
Do SBP-drops during hospitalization for acute heart failure worsen outcomes, and does serelaxin treatment modify this risk?
Blood pressure drops during acute heart failure hospitalization are associated with worse outcomes, though this risk appears attenuated in patients treated with the intravenous vasodilator serelaxin.
Answers are grounded in this paper and cite their sources.
SBP-drops may identify higher-risk acute HF patients receiving serelaxin; leaves open whether they warrant management changes or modify treatment effects.
Background: Hypotensive events and drops in systolic blood pressure (SBP-drop) are frequent in patients hospitalized with acute heart failure. We investigated whether SBP-drops are associated with outcomes in patients treated with serelaxin. Methods: Patient-level retrospective analyses of 4 prospective trials investigating serelaxin in acute heart failure. Main inclusion criteria were SBP 125 to 180 mm Hg, pulmonary congestion, and elevated NT-proBNP (N-terminal pro-B-type natriuretic peptide). SBP-drops were prospectively defined as SBP<100 mm Hg, or, if SBP remained >100 mm Hg, a drop from baseline of 40 mm Hg from baseline. Outcomes were a short-term composite outcome (worsening heart failure, hospital readmission for heart failure or all-cause mortality through 14 days) and 180-day mortality. Results: Overall, 2559/11 226 (23%) patients had an SBP-drop. SBP-drop, versus no SBP-drop, was associated with a worse outcome: cumulative incidence of 180-day mortality (11% versus 9%, hazard ratio [HR]. 1.21 [95% CI, 1.05–1.39]; P =0.009) and the short-term outcome (11% versus 9%, HR, 1.29 [95% CI, 1.13–1.49]; P <0.001). Of the 2 SBP-drop components, an SBP<100 mm Hg was associated with the worst outcome compared with a 40 mm Hg drop: short-term outcome (11% versus 10%) and HRs of 1.32 (95% CI, 1.13–1.55; P =0.0005) and 1.22 (95% CI, 0.97–1.56; P =0.09), for each component respectively, with a P value for interaction of 0.05. SBP-drops were associated with a worse short-term outcome in the placebo group (HR, 1.46 [95% CI, 1.19–1.79]; P =0.0003), but not in the serelaxin-group (HR, 1.18 [95% CI, 0.97–1.42]; P =0.10); P interaction=0.003. Conclusions: SBP-drops in patients with acute heart failure and normal to high SBP at admission is associated with worse short- and long-term outcomes especially for SBP <100 mm Hg. However, in patients treated with the intravenous vasodilator serelaxin, SBP-drops seemed less harmful. Registration: URL: https://www.clinicaltrials.gov ; Unique identifiers: NCT02064868, NCT02007720, NCT01870778, NCT00520806.
No takes yet. Share an insight, caveat, or question.
Grand et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: