Why the study?
The study investigated whether artificial intelligence applied to the electrocardiogram could rapidly exclude SARS-CoV-2 infection.
Does an artificial intelligence-enhanced electrocardiogram accurately detect or exclude acute SARS-CoV-2 infection?
Does an artificial intelligence-enhanced electrocardiogram accurately detect or exclude acute SARS-CoV-2 infection?
An AI-enhanced ECG can rapidly exclude acute COVID-19 infection with a high negative predictive value, offering a potential triage tool for pandemic screening.
Answers are grounded in this paper and cite their sources.
AI-ECG screening yields high negative predictive value for COVID-19; leaves open prospective validation before clinical adoption.
OBJECTIVE: To rapidly exclude severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection using artificial intelligence applied to the electrocardiogram (ECG). METHODS: A global, volunteer consortium from 4 continents identified patients with ECGs obtained around the time of polymerase chain reaction-confirmed COVID-19 diagnosis and age- and sex-matched controls from the same sites. Clinical characteristics, polymerase chain reaction results, and raw electrocardiographic data were collected. A convolutional neural network was trained using 26,153 ECGs (33.2% COVID positive), validated with 3826 ECGs (33.3% positive), and tested on 7870 ECGs not included in other sets (32.7% positive). Performance under different prevalence values was tested by adding control ECGs from a single high-volume site. RESULTS: The area under the curve for detection of acute COVID-19 infection in the test group was 0.767 (95% CI, 0.756 to 0.778; sensitivity, 98%; specificity, 10%; positive predictive value, 37%; negative predictive value, 91%). To more accurately reflect a real-world population, 50,905 normal controls were added to adjust the COVID prevalence to approximately 5% (2657/58,555), resulting in an area under the curve of 0.780 (95% CI, 0.771 to 0.790) with a specificity of 12.1% and a negative predictive value of 99.2%. CONCLUSION: Infection with SARS-CoV-2 results in electrocardiographic changes that permit the artificial intelligence-enhanced ECG to be used as a rapid screening test with a high negative predictive value (99.2%). This may permit the development of electrocardiography-based tools to rapidly screen individuals for pandemic control.
No takes yet. Share an insight, caveat, or question.
Attia et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: