Why the study?
Can intravascular ultrasound elastography distinguish different plaque components in human arteries in vitro?
Can intravascular ultrasound elastography distinguish different plaque components in human arteries in vitro?
IVUS elastography can distinguish between fibrous, fibro-fatty, and fatty plaque components based on strain values, offering potential for advanced plaque characterization.
Strain differentiates plaque types in vitro; leaves open clinical IVUS elastography utility pending in vivo validation.
BACKGROUND: The composition of plaque is a major determinant of coronary-related clinical syndromes. Intravascular ultrasound (IVUS) elastography has proven to be a technique capable of reflecting the mechanical properties of phantom material and the femoral arterial wall. The aim of this study was to investigate the capability of intravascular elastography to characterize different plaque components. METHODS AND RESULTS: Diseased human femoral (n=9) and coronary (n=4) arteries were studied in vitro. At each location (n=45), 2 IVUS images were acquired at different intraluminal pressures (80 and 100 mm Hg). With the use of cross-correlation analysis on the high-frequency (radiofrequency) ultrasound signal, the local strain in the tissue was determined. The strain was color-coded and plotted as an additional image to the IVUS echogram. The visualized segments were stained on the presence of collagen, smooth muscle cells, and macrophages. Matching of elastographic data and histology were performed with the use of the IVUS echogram. The cross sections were segmented in regions (n=125) that were based on the strain value on the elastogram. The dominant plaque types in these regions (fibrous, fibro-fatty, or fatty) were obtained from histology and correlated with the average strain and echo intensity. The strain for the 3 plaque types as determined by histology differed significantly (P=0.0002). This difference was mainly evident between fibrous and fatty tissue (P=0.0004). The plaque types did not reveal echo-intensity differences in the IVUS echogram (P=0.882). CONCLUSIONS: Different strain values are found between fibrous, fibro-fatty, and fatty plaque components, indicating the potential of intravascular elastography to distinguish different plaque morphologies.
No takes yet. Share an insight, caveat, or question.
Korte et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: