Why the study?
Can Automated Cardiac Motion Quantification (aCMQ) speckle tracking echocardiography detect differences in ventricular myocardial deformation between normal fetuses and those with abnormal heart structure or rhythm?
Can Automated Cardiac Motion Quantification (aCMQ) speckle tracking echocardiography detect differences in ventricular myocardial deformation between normal fetuses and those with abnormal heart structure or rhythm?
Automated Cardiac Motion Quantification is a feasible and reproducible tool for evaluating fetal ventricular myocardial deformation, demonstrating reduced strain in fetuses with cardiac abnormalities.
aCMQ fetal strain analysis should not yet alter clinical assessment; leaves open its diagnostic utility in larger prospective studies.
METHODS: The study included 59 patients with normal fetal heart structure, blood flow, and heart rhythm (fetal abnormality-negative group) and 50 patients with abnormal fetal heart structure, blood flow, and/or heart rhythm (fetal abnormality-positive group). Automated Cardiac Motion Quantification (aCMQ) was performed in both groups to obtain left and right ventricular endocardial global longitudinal strain (GLSendo), mid-myocardial global longitudinal strain (GLSmid), and epicardial global longitudinal strain (GLSepi). Parameters between the two groups were compared and correlation analyses performed. A deformation analysis was performed by two trained observers, and reproducibility was assessed. RESULTS: The fetal left ventricular and right ventricular global longitudinal strain (LV-GLS and RV-GLS, respectively) decreased in a gradient from the endocardium to the epicardium. LV-GLS and RV-GLS of all myocardial layers were lower in the fetal abnormality-positive than -negative group (all P < 0.05). Correlation analysis showed that neither LV-GLS nor RV-GLS was significantly correlated with gestational age in the fetal abnormality-negative group (all P > 0.05), whereas left ventricular GLSendo, GLSmid, and GLSepi were negatively correlated with gestational age in the fetal abnormality-positive group (r = -.39 to -.44, all P < 0.05). Repeatability testing showed that the inter-observer and intra-observer intra-class correlation coefficients for LV-GLS and RV-GLS in each myocardial layer were >.75 (all P < 0.001). CONCLUSIONS: As a new speckle tracking echocardiography tool, aCMQ has feasibility and repeatability in evaluating myocardial deformation of the fetal ventricle. This technique might provide helpful information on ventricular myocardial deformation in fetal hearts with abnormal structure or rhythm for clinical guidance in pregnancy.
No takes yet. Share an insight, caveat, or question.
Luo et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: