Key result
In a passive ex vivo beating porcine heart model, the peak areal strain at the midsection of the tricuspid valve leaflets was 9.8 ± 2.0%.
Population
Porcine hearts (n = 8)
Design
Preclinical
Authors
Loading...
Offers quantitative strain data for tricuspid valve modeling; leaves open in vivo human validation.
This novel ex vivo technique successfully measured porcine tricuspid valve leaflet strains without isolating the valve annuli, providing baseline physiological deformation values.
Khoiy et al. (2016) studied Tricuspid valve mechanics (n=8). Passive ex vivo beating heart model was evaluated on Peak areal strain at the midsection of the valve leaflets. In a passive ex vivo beating porcine heart model, the peak areal strain at the midsection of the tricuspid valve leaflets was 9.8 ± 2.0%.