Key result
Transesophageal echocardiography provided reliable assessment of the heart in swine, with pulsed wave Doppler-derived cardiac output correlating strongly with the invasive thermodilution method (r = 0.812).
Why the study?
Standard left and right ventricular transesophageal echocardiographic measurements and global myocardial work index estimation using pressure-strain loops had not been determined in swine.
Effect estimate: r = 0.812
Absolute Event Rate: 7% vs 7%
p-value: p=0.004
Transesophageal echocardiography provides reliable morphological, functional, and hemodynamic assessment of the heart in swine, including non-invasive estimation of myocardial work indices that correlate well with invasive measurements.
Supports TEE feasibility in swine; leaves open human validation for cardiac output monitoring.
This study aimed to determine standard left (LV) and right ventricular (RV) transesophageal echocardiographic (TEE) measurements in swine. Additionally, global myocardial work index (GWI) was estimated using pressure-strain loops (PSL). A comprehensive TEE examination was conducted in ten anesthetized, intubated and mechanically ventilated healthy female German landrace swine, weighing 44 to 57 kg. For GWI calculation, we performed LV and RV segmental strain analysis and used invasively measured LV and RV pressure to obtain PSL. The GWI and further myocardial work indices were calculated from the area of the PSL using commercially available software. Furthermore, hemodynamic measurements were obtained using indwelling catheters. We obtained complete standardized baseline values for left and right ventricular dimensions and function. Biplane LV ejection fraction was 63 ± 7 % and the LV end-diastolic volume was 70.5 ± 5.9 ml. Tissue Doppler estimated peak tricuspid annular systolic velocity was 13.1 ± 1.8 cm/s. The Doppler estimated LV and RV stroke volume index were 75.6 ± 7.2 ml/m 2 and 76.7 ± 7.8 ml/m 2 respectively. Pulsed wave Doppler derived cardiac output correlated well with cardiac output estimated using the thermodilution method (7.0 ± 1.2 l/min vs. 7.0 ± 1.1 l/min, r = 0.812, p = 0.004). The LV global longitudinal strain was -21.3 ± 3.9 % and the RV global longitudinal strain was -15.4 ± 2.5 %. LV GWI was 1885(1281–2121) mmHg*% and 297 ± 62 mmHg*% for the RV. LV global myocardial work efficiency was 82.6 ± 4 % and 83(72–88) % for the RV. TEE offers sufficient morphological, functional and hemodynamic assessment of the heart in swine. Myocardial contractility and mechanics can be reliably evaluated with the non-invasive GWI derived from echocardiography without additional invasive measures.
No takes yet. Share an insight, caveat, or question.
Billig et al. (2020) studied Healthy (n=10). Transesophageal echocardiography vs. Thermodilution method was evaluated on Correlation between pulsed wave Doppler derived cardiac output and thermodilution method (r = 0.812, p=0.004). Transesophageal echocardiography provided reliable assessment of the heart in swine, with pulsed wave Doppler-derived cardiac output correlating strongly with the invasive thermodilution method (r = 0.812).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: