Key result
The MusAsi scheme successfully coupled a stochastic cross-bridge model with a macroscopic finite element heart model, enabling the computation of one heartbeat within 1.5 hours using 320 cores.
Why the study?
Large timescale differences between rapid stochastic contractile protein changes and macroscopic cardiac outcomes, along with dynamic muscle stiffness changes, have hindered efficient coupling algorithms in multiscale heart simulations.
The MusAsi scheme provides an efficient and stable computational method to couple stochastic molecular cross-bridge models with macroscopic finite element heart models.
Answers are grounded in this paper and cite their sources.
Enables efficient multiscale cardiac simulations; leaves open clinical validation and translation.
In a multiscale simulation of a beating heart, the very large difference in the time scales between rapid stochastic conformational changes of contractile proteins and deterministic macroscopic outcomes, such as the ventricular pressure and volume, have hampered the implementation of an efficient coupling algorithm for the two scales. Furthermore, the consideration of dynamic changes of muscle stiffness caused by the cross-bridge activity of motor proteins have not been well established in continuum mechanics. To overcome these issues, we propose a multiple time step scheme called the multiple step active stiffness integration scheme (MusAsi) for the coupling of Monte Carlo (MC) multiple steps and an implicit finite element (FE) time integration step. The method focuses on the active tension stiffness matrix, where the active tension derivatives concerning the current displacements in the FE model are correctly integrated into the total stiffness matrix to avoid instability. A sensitivity analysis of the number of samples used in the MC model and the combination of time step sizes confirmed the accuracy and robustness of MusAsi, and we concluded that the combination of a 1.25 ms FE time step and 0.005 ms MC multiple steps using a few hundred motor proteins in each finite element was appropriate in the tradeoff between accuracy and computational time. Furthermore, for a biventricular FE model consisting of 45,000 tetrahedral elements, one heartbeat could be computed within 1.5 h using 320 cores of a conventional parallel computer system. These results support the practicality of MusAsi for uses in both the basic research of the relationship between molecular mechanisms and cardiac outputs, and clinical applications of perioperative prediction.
No takes yet. Share an insight, caveat, or question.
Yoneda et al. (2021) studied Heart simulation (computational modeling). Multiple step active stiffness integration scheme (MusAsi) vs. Explicit active tension approach was evaluated on Computational stability, accuracy, and time. The MusAsi scheme successfully coupled a stochastic cross-bridge model with a macroscopic finite element heart model, enabling the computation of one heartbeat within 1.5 hours using 320 cores.