Key result
A machine learning model using ballistocardiogram and impedance plethysmogram signals accurately estimated systolic and diastolic blood pressure with mean absolute differences of 3.35 and 2.67 mmHg, respectively.
Why the study?
Conventional cuff-based sphygmomanometers are unsuitable for mobile health, prompting the need for accurate cuffless blood pressure estimation using signal processing and machine learning.
Does a machine learning model using BCG and IPG from a weight-fat scale accurately estimate blood pressure in healthy subjects?
Observational (n=17)
No
Does a machine learning model using BCG and IPG from a weight-fat scale accurately estimate blood pressure in healthy subjects?
Effect estimate: MAD 3.35 mmHg for SBP and 2.67 mmHg for DBP
A machine learning approach using ballistocardiogram and impedance plethysmogram signals from a weight-fat scale provides accurate cuffless blood pressure estimation.
Introduction: Blood pressure (BP) serves as a crucial parameter in the management of three prevalent chronic diseases, hypertension, cardiovascular diseases, and cerebrovascular diseases. However, the conventional sphygmomanometer, utilizing a cuff, is unsuitable for the approach of mobile health (mHealth). Methods: Cuffless blood pressure measurement, which eliminates the need for a cuff, is considered a promising avenue. This method is based on the relationship between pulse arrival time (PAT) parameters and BP. In this study, pulse transit time (PTT) was derived from ballistocardiograms (BCG) and impedance plethysmograms (IPG) obtained from a weight-fat scale. This study aims to address two challenges using deep learning and machine learning technologies: first, identifying BCG and IPG signals with good quality, and then extracting PTT parameters from them to estimate BP. A stacked model comprising a one-dimensional convolutional neural network (1D CNN) and gated recurrent unit (GRU) was proposed to classify the quality of BCG and IPG signals. Seven parameters, including calibration-based and calibration-free PTT parameters and heart rate (HR), were examined to estimate BP using random forest (RF) and XGBoost models. Seventeen healthy subjects participated in the study, with their BP elevated through exercise. A digital sphygmomanometer was employed to measure BP as reference values. Our methodology was validated using data collected from our custom-made device. Results: The results demonstrated a signal quality classification accuracy of 0.989. Furthermore, in the five-fold cross-validation, Pearson correlation coefficients of 0.953 ± 0.007 and 0.935 ± 0.007 were achieved for systolic BP (SBP) and diastolic BP (DBP) estimations, respectively. The mean absolute differences (MADs) of XGBoost model were calculated as 3.54 ± 0.34 and 2.57 ± 0.17 mmHg for SBP and DBP, respectively. Discussion: The proposed method significantly improved the accuracy of cuffless BP measurement, indicating its potential integration into weight-fat scales as an unconstrained device for effective utilization in mHealth applications.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2025) conducted an observational in Healthy (blood pressure elevated through exercise) (n=17). Cuffless blood pressure estimation using BCG and IPG with XGBoost vs. Digital sphygmomanometer was evaluated on Accuracy of systolic and diastolic blood pressure estimation (MAD 3.35 mmHg for SBP and 2.67 mmHg for DBP). A machine learning model using ballistocardiogram and impedance plethysmogram signals accurately estimated systolic and diastolic blood pressure with mean absolute differences of 3.35 and 2.67 mmHg, respectively.