Why the study?
Machine learning methods applied to photoplethysmogram signals were evaluated to improve the accuracy and long-term variability of cuffless sphygmomanometers for estimating blood pressure during exercise.
Does a cuffless sphygmomanometer using PPG and LSTM neural networks accurately estimate blood pressure during exercise in young adult males compared to a continuous sphygmomanometer?
Does a cuffless sphygmomanometer using PPG and LSTM neural networks accurately estimate blood pressure during exercise in young adult males compared to a continuous sphygmomanometer?
A cuffless sphygmomanometer using PPG and machine learning can estimate blood pressure during exercise with accuracy comparable to regulatory standards.
Cuffless exercise BP estimation remains investigational; leaves open accuracy, generalizability, and clinical utility pending validation.
Accurately measuring blood pressure (BP) is essential for maintaining physiological health, which is commonly achieved using cuff-based sphygmomanometers. Several attempts have been made to develop cuffless sphygmomanometers. To increase their accuracy and long-term variability, machine learning methods can be applied for analyzing photoplethysmogram (PPG) signals. Here, we propose a method to estimate the BP during exercise using a cuffless device. The BP estimation process involved preprocessing signals, feature extraction, and machine learning techniques. To ensure the reliability of the signals extracted from the PPG, we employed the skewness signal quality index and the RReliefF algorithm for signal selection. Thereafter, the BP was estimated using the long short-term memory (LSTM)-based neural network. Seventeen young adult males participated in the experiments, undergoing a structured protocol composed of rest, exercise, and recovery for 20 min. Compared to the BP measured using a non-invasive voltage clamp-type continuous sphygmomanometer, that estimated by the proposed method exhibited a mean error of 0.32 ± 7.76 mmHg, which is equivalent to the accuracy of a cuff-based sphygmomanometer per regulatory standards. By enhancing patient comfort and improving healthcare outcomes, the proposed approach can revolutionize BP monitoring in various settings, including clinical, home, and sports environments.
No takes yet. Share an insight, caveat, or question.
Hayashi et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: