Key result
Blood pressure measurements over a thin sleeve resulted in significantly lower systolic (116.9 vs 122.8 mm Hg, p=0.001) and diastolic pressures than below a rolled-up sleeve.
Why the study?
Although guidelines recommend measuring blood pressure on a bare upper arm, in practice it is often more convenient to measure below a rolled-up sleeve or over a sleeve.
Does measuring blood pressure over a thin sleeve compared to below a rolled-up sleeve affect blood pressure readings?
RCT (n=1)
determined by chance
No
Does measuring blood pressure over a thin sleeve compared to below a rolled-up sleeve affect blood pressure readings?
Measuring blood pressure over a thin sleeve yields significantly lower readings than below a rolled-up sleeve, and matches measurements taken on a completely bare arm.
Answers are grounded in this paper and cite their sources.
BP over thin sleeve underestimates readings versus rolled-up; challenges sleeve convenience and supports strict bare-arm protocols in practice and guidelines.
Background Blood pressure [BP] should be measured using a bare upper arm with an appropriately sized cuff. In practice, it is more convenient to measure BP on a bare arm below a rolled-up sleeve or on a sleeved arm.Aim A n-of-1 randomized controlled trial was performed to assess the difference between BP measurements over a sleeve or below a rolled-up sleeve.Methods The study subject was male, white, 72 years old, BMI 26 kg/m2, arm circumference 29 cm, and under stable antihypertensive treatment. The mean of three BP measurements over a thin sleeve was compared with measurements below a rolled-up sleeve. Additional measurements on a completely bare arm, with thicker sleeves and up to three layers were performed. The order of measurements was determined by chance and two oscillometric devices were used. Descriptive statistics, Bland-Altman test and 2-side T test were used for comparisons.Results 504 measurements were performed: 50 % over the sleeve and 50 % below the rolled-up sleeve. The mean systolic blood pressure (SBP) was respectively 116.9 ± 9. 2 [95% CI 115.7–118.0, range 96–135] and 122.8 ± 9.2 [95% CI 121.7–124.0, range 103–139, p = 0.001] mm Hg. The mean diastolic blood pressure [DBP] was respectively 67.6 ± 6.8 [95% CI 66.8–68.4, range 52–84] and 71.8 ± 6.8 [95% CI 71.0–72.7, range 55–85, p = 0.001] mm Hg. There was no significant difference between the measurements over the sleeve and on the completely bare arm [n = 94, p = 0.97]. Sleeve thickness with 2 layers up to 3 mm thick did not affect the results.Conclusions Blood pressure measurements over a thin sleeve were significantly lower than measurements below a rolled-up sleeve and match measurements on a completely bare arm.
No takes yet. Share an insight, caveat, or question.
R. Lins (2023) conducted an RCT in hypertension (n=1). Blood pressure measurement over a thin sleeve vs. Blood pressure measurement below a rolled-up sleeve was evaluated on mean systolic blood pressure (SBP) (p=0.001). Blood pressure measurements over a thin sleeve resulted in significantly lower systolic (116.9 vs 122.8 mm Hg, p=0.001) and diastolic pressures than below a rolled-up sleeve.