Why the study?
FFRCT and diagnostic accuracy rely on good image quality during CCTA, prompting investigation into whether heart rate and coronary artery calcium score reduce image quality and diagnostic performance across advanced CT scanners.
Does 256-row MDCT compared to 96-row DSCT improve image quality and diagnostic accuracy in patients undergoing coronary CT angiography?
Does 256-row MDCT compared to 96-row DSCT improve image quality and diagnostic accuracy in patients undergoing coronary CT angiography?
Severe coronary calcification (CAC ≥400) significantly impairs image quality and diagnostic accuracy of both 96-row DSCT and 256-row MDCT, while heart rate ≥70 bpm specifically degrades MDCT image quality.
Answers are grounded in this paper and cite their sources.
CAC ≥400 may impair CCTA quality and FFRCT accuracy on advanced scanners; leaves open optimal thresholds in calcified vessels.
BACKGROUND: CT-derived fractional flow reserve (FFRCT) and diagnostic accuracy rely on good image quality during coronary CT angiography (CCTA). OBJECTIVE: To investigate whether heart rate (HR) and coronary artery calcium (CAC) score decrease image quality and diagnostic performance of two advanced CT scanners including 96-row detector dual source CT (DSCT) and 256-row multidetector CT (MDCT). METHODS: First, 79 patients who underwent CCTA (42 with DSCT and 37 with MDCT) and invasive coronary angiography (ICA) are enrolled. Next, coronary segments with excellent image quality are evaluated and the percentage is calculated. Then, diagnostic accuracy in detecting significant diameter stenosis is presented with ICA as the reference standard. RESULTS: Compared with the DSCT, the percentage of coronary segments with excellent image quality is lower (P = 0.010) while diagnostic accuracy on per-segment level is improved (P = 0.037) using MDCT. CAC score≥400 is the only independent factor influencing the percentage of coronary segments with excellent image quality [odds ratio (OR): DSCT, 3.096 and MDCT, 1.982] and segmental diagnostic accuracy (OR: DSCT, 2.630 and MDCT, 2.336) for both scanners. HR≥70 bpm (OR: 5.506) is the independent factor influencing the percentage of coronary segments with excellent image quality with MDCT. CONCLULSION: During CCTA, CAC score≥400 still decreases the proportion of coronary segments with excellent image quality and diagnostic accuracy with advanced CT scanners. HR≥70 bpm is another factor causing image quality decreasing with MDCT.
No takes yet. Share an insight, caveat, or question.
Qian et al. (2021) studied this question.