Why the study?
Attenuation artifacts cause false positives in SPECT MPI, and the relative diagnostic performance of CT attenuation correction versus gated MPI for coronary artery disease remained to be evaluated.
Does gated myocardial perfusion imaging improve diagnostic accuracy for coronary artery disease compared to computed tomography attenuation correction in patients undergoing SPECT?
Does gated myocardial perfusion imaging improve diagnostic accuracy for coronary artery disease compared to computed tomography attenuation correction in patients undergoing SPECT?
Gated SPECT myocardial perfusion imaging provides superior diagnostic efficacy compared to CT attenuation correction for differentiating attenuation artifacts from fixed defects, particularly in men and for right coronary artery disease.
GMPI may aid artifact discrimination in select SPECT MPI cases; leaves open whether it outperforms CT-AC for routine CAD diagnosis.
BACKGROUND: In single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) studies, attenuation artifacts frequently cause false positives, which can be partially overcome by computed tomography attenuation correction (CT-AC) or gated acquisition [gated myocardial perfusion imaging (GMPI)]. The purpose of this study is to evaluate their relative diagnostic performances for coronary artery disease (CAD). PATIENTS AND METHODS: We enrolled 181 patients who underwent gated SPECT with CT-AC in this study. Two observers who were blinded to the clinical data interpreted the GMPI and CT-AC images. Coronary angiography was considered as the reference standard. The diagnostic efficacy was evaluated based on sex, BMI, and individual coronary arteries. RESULTS: The diagnostic accuracy of GMPI was higher than that of nonattenuation correction overall, as well as for men, overweight individuals, and right CAD (P<0.05). Compared with CT-AC, GMPI overall had a higher specificity (96.3 vs. 86.9%, P=0.014) but the same sensitivity, achieving an increased accuracy and area under the curve (AUC, P>0.05). For diagnosing right CAD, GMPI had a higher diagnostic efficacy (AUC: 0.733 vs. 0.596, P<0.001) because of its higher sensitivity (52.0 vs. 26.0%, P=0.008); for men, the diagnostic efficacy of GMPI was significantly higher than that of CT-AC (AUC: 0.754 vs. 0.681, P=0.038). CONCLUSION: Both CT-AC and GMPI led to an increased diagnostic efficacy compared with nonattenuation correction in differentiating attenuation artifacts from fixed perfusion defects. These improvements were, however, more obvious for GMPI than for CT-AC, especially in men and right CAD.
No takes yet. Share an insight, caveat, or question.
Xin et al. (2019) studied this question.