Why the study?
Commissural orientation <160° is a recognized risk factor for bicuspid aortic valve repair failure, prompting the proposal to reorient commissures at 180°.
Does 180° commissural reorientation improve transvalvular aortic gradients compared to 120° orientation in a bicuspid aortic valve repair model?
Does 180° commissural reorientation improve transvalvular aortic gradients compared to 120° orientation in a bicuspid aortic valve repair model?
In an in vitro porcine model, 180° commissural reorientation during bicuspid aortic valve repair improved transvalvular gradients under stress conditions compared to native 120° orientation.
Experimental model of commissural reorientation in BAV shows hemodynamic effects; leaves open clinical durability and practice change.
OBJECTIVES: Commissural orientation <160° is a recognized risk factor for bicuspid aortic valve repair failure. Based on this observation, repairing this subtype of aortic valve by reorienting the 2 commissures at 180° has recently been proposed. METHODS: Nine porcine hearts with aortic annulus diameters of 25 mm were selected. A pathological model of a Sievers 1 bicuspid aortic valve was obtained by suturing the coaptation line between the left and right leaflets. Each heart underwent reimplantation procedures both in the native (120°) and the reoriented (180°) configuration. After the operation, each sample was tested on a pulse duplicator at rest (heart rate 60 beats per min) and with mild exercise (heart rate 90 beats per min) conditions. RESULTS: No statistically significant difference was noted in mean and peak transvalvular aortic gradients between the 2 configurations at rest (18.6 ± 5 vs 17.5 ± 4 for the mean aortic gradient; 42.8 ± 12.7 vs 36.3 ± 5.8 for the peak aortic gradient) but the group with the 120°-oriented commissures had significantly higher mean transaortic gradients compared to the group with the 180°-oriented commissures at initial exercise stress conditions (30.1 ± 9.1 vs 24.9 ± 3.8; p value 0.002). CONCLUSIONS: The 180° commissural reorientation of the asymmetrical bicuspid aortic valve does not improve the transvalvular aortic gradient in an acute model at rest conditions, but it could do so under stress situations. Even if it is surgically more complex and time-consuming, this approach could be a good strategy to improve long-term results, particularly in young patients.
No takes yet. Share an insight, caveat, or question.
Romagnoni et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: