Why the study?
PDA closure causes a sudden drop in LV preload that may affect LV functions, prompting evaluation of immediate- and short-term changes using speckle tracking echocardiography.
Does percutaneous PDA closure affect immediate and short-term LV function measured by speckle tracking echocardiography in patients with PDA?
Does percutaneous PDA closure affect immediate and short-term LV function measured by speckle tracking echocardiography in patients with PDA?
Percutaneous PDA closure leads to an immediate and sustained decrease in LV end-diastolic volume without significant changes in global LV strain or strain rate.
Answers are grounded in this paper and cite their sources.
LV strain unchanged post-PDA closure; leaves open whether time-to-peak strain signals adaptive remodeling needing prospective trials.
Background: Patent ductus arteriosus (PDA) closure results in a sudden drop in left ventricular (LV) preload, and this may affect the LV functions. Aim: The aim was to evaluate the immediate- and short-term changes in LV functions by speckle tracking echocardiography (STE) post percutaneous PDA closure. Materials and Methods: The study included 45 patients with PDA who were referred for PDA trans-catheter closure. All the patients included in the study underwent full echocardiographic examination and speckle tracking analysis before PDA closure, immediately after closure, and 1 month after the PDA closure. Results: There was no statistically significant change in LV functions by two-dimensional transthoracic echocardiography; the LV end-diastolic volume (EDV) decreased significantly in the immediate follow-up from 41.608 ± 25.8846 ml before duct closure to 36.317 ± 21.6945 ml. The drop in the LV EDV continued in the 1-month follow-up. The LV end-systolic volume decreased as well, however it took 1 month for this drop to be statistically significant. The LV end-diastolic dimension also decreased significantly after duct closure. Regarding STE results, the global LV strain and strain rate values did not significantly change. The global strain values had a mean of −22.944% ± 3.5128% before duct closure and decreased to a mean −22.028% ± 2.8932% immediately after duct closure. Conclusion: The study concluded that STE could be used to detect subtle changes in LV deformation. Time to peak systolic strain is an understudied parameter that needs further evaluation to provide a better understanding regarding its role in myocardial function assessment.
No takes yet. Share an insight, caveat, or question.
Ezzeldin et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: