Does 50 Hz burst induction compared to T-wave shock induction affect defibrillation threshold in patients undergoing ICD implantation?
Does 50 Hz burst induction compared to T-wave shock induction affect defibrillation threshold in patients undergoing ICD implantation?
Both 50 Hz burst and T-wave shock are reliable methods for defibrillation threshold determination, but T-wave shock is less likely to induce ventricular tachycardia during testing.
Answers are grounded in this paper and cite their sources.
Burst and T-wave shock induction yield equivalent defibrillation thresholds; confirms both as reliable methods with T-wave shock reducing VT induction risk.
INTRODUCTION: Since no clinical data are available on the comparison of the "shock on T-wave" and "high frequency burst" ventricular fibrillation (VF) induction modes during defibrillation threshold (DFT) testing, we aimed to compare these two methods during implantable cardioverter defibrillator implantation. METHODS: The DFT was determined with a step-down protocol using biphasic, anodal polarity (100%, 40%, 20% voltage control) shocks. Patients were randomized: VF was induced by 50 Hz burst in group B (n = 45) and T-wave shock in group T (n = 41). The DFT was defined as the lowest energy level that terminated VF; confirmed DFT (DFTc) was defined as the minimal energy level that consecutively terminated VF twice. Success rate of DFTc was calculated during an intraindividual test for the alternate induction method. RESULTS: A total of 546 episodes of VF were induced: n = 278 (B) vs n = 268 (T). Incidence of VT during inductions was 9.9% (B) vs 2.7% (T), P < 0.05. Neither the DFT, 8.8 +/- 4.0 J (B) vs 9.7 +/- 4.2 J (T), nor the DFTc, 10.6 +/- 5.1 J (B) vs 10.8 +/- 4.2 J (T), proved to be significantly different. A significant correlation was found between VF cycle length (CL) and the concomitant DFT (r = 0.298, P < 0.05) in group T only. Subgroup analysis of patients under chronic class III antiarrhythmic treatment showed no increase of the DFT in either group and significantly lower incidence of VT induction in group T regardless of antiarrhythmic treatment. CONCLUSION: The DFT and the VFCL proved to be independent of the VF induction method. The T-wave shock was more unlikely to induce VT during DFT testing. These results suggest that both methods are reliable in DFT determination, though T-wave shock application is a more reliable method for DFT testing.
No takes yet. Share an insight, caveat, or question.
Zima et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: