Answers are grounded in this paper and cite their sources.
Anecdotal reports and in vitro and clinical studies indicate that 5.0 mm x 6.0 mm ovoid posterior chamber lenses may have a higher incidence of photic phenomena, perhaps caused when the thicker truncated lens edge presents within the pupillary aperture. To evaluate these subjective phenomena, we gave a questionnaire to a random sample of patients who received one of three different poly(methyl methacrylate) (PMMA) posterior chamber lens optic styles (5.0 x 6.0 mm ovoid, 7.0 mm round, 5.5 mm round) placed in the bag. About 20% of all IOL groups reported photic phenomena, with symptoms similar between groups. The percentage reporting persistent phenomena was also comparable. We concluded that eyes in which any IOL optic is covered by the anterior capsular edge do not have a higher incidence of photic phenomena, which may instead result from the PMMA or vitreoretinal traction after cataract extraction.
No takes yet. Share an insight, caveat, or question.
Paul Arnold (1994) studied this question.