Why the study?
Does pmTCD improve the detection of contrast bubble emboli and diagnosis of PFO compared to sgTCD and TEE in patients undergoing transcatheter PFO closure?
Does pmTCD improve the detection of contrast bubble emboli and diagnosis of PFO compared to sgTCD and TEE in patients undergoing transcatheter PFO closure?
pmTCD is a highly sensitive, noninvasive alternative to TEE for diagnosing PFO and assessing residual shunt after transcatheter closure.
Answers are grounded in this paper and cite their sources.
pmTCD may improve microemboli detection sensitivity; hypothesis-generating for PFO diagnosis and requires randomized validation before practice change.
BACKGROUND AND PURPOSE: Transcatheter closure of patent foramen ovale (PFO) can benefit from a less invasive diagnostic method than transesophageal echocardiography (TEE). Thirty-three gate power m-mode transcranial Doppler (pmTCD) was evaluated for its accuracy in diagnosis of PFO and utility in evaluating residual intracardiac right-to-left shunt (RLS) following transcatheter closure. METHODS: The sensitivity of pmTCD and single-gate TCD (sgTCD) to detect contrast bubble emboli through RLS was compared during transcatheter PFO closure. During 100 preclosure diagnostic evaluations and in 81 postclosure assessments, embolic tracks on pmTCD were counted following intravenous contrast injections and were graded using a 6-level logarithmic scale. The accuracy of TEE and pmTCD was separately compared to PFO anatomical findings during transcatheter closures. RESULTS: There were significantly more microemboli detectable on pmTCD (322 +/- 166; 95% confidence interval [CI], 388-257) than on sgTCD (186 +/- 109; 95% CI, 229-143; P < .001). McNemar change tests suggest that the diagnostic capabilities of pmTCD and TEE for detecting PFO are comparable and correspond to the anatomical findings determined during cardiac catheterization (P = .69 and .45, respectively). During 6-month postclosure evaluation (mean = 185 days), 66% of the patients demonstrated successful closure without significant RLS (ie, grades 0, I, or II), and 34% were found to have incomplete closure with significant RLS (ie, grades III, IV, or V). CONCLUSIONS: pmTCD provides greater sensitivity to contrast bubble emboli than does sgTCD. Among candidates for transcatheter closure, pmTCD provides an improved noninvasive method for diagnosing PFO and evaluating transcatheter closure.
No takes yet. Share an insight, caveat, or question.
Merrill P. Spencer (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: