Why the study?
Kidney dysfunction is common in aortic stenosis and TAVI often affects kidney function, potentially due to microcirculatory changes.
Does microcirculatory tissue oxygenation measured by hyperspectral imaging correlate with kidney function after TAVI in patients with severe aortic stenosis?
Does microcirculatory tissue oxygenation measured by hyperspectral imaging correlate with kidney function after TAVI in patients with severe aortic stenosis?
Hyperspectral imaging of skin microcirculation reveals that tissue oxygenation correlates with kidney function and clinical outcomes after TAVI.
Answers are grounded in this paper and cite their sources.
HSI detects post-TAVI microcirculatory shifts linked to kidney function; hypothesis-generating and leaves open whether it predicts outcomes or alters management.
Introduction Kidney dysfunction is common in patients with aortic stenosis (AS) and correction of the aortic valve by transcatheter aortic valve implantation (TAVI) often affects kidney function. This may be due to microcirculatory changes. Methods We evaluated skin microcirculation with a hyperspectral imaging (HSI) system, and compared tissue oxygenation (StO 2 ), near-infrared perfusion index (NIR), tissue hemoglobin index (THI) and tissue water index (TWI) in 40 patients undergoing TAVI versus 20 control patients. HSI parameters were measured before TAVI (t1), directly after TAVI (t2), and on postinterventional day 3 (t3). The primary outcome was the correlation of tissue oxygenation (StO 2 ) to the creatinine level after TAVI. Results We performed 116 HSI image recordings in patients undergoing TAVI for the treatment of severe aortic stenosis and 20 HSI image recordings in control patients. Patients with AS had a lower THI at the palm ( p = 0.034) and a higher TWI at the fingertips ( p = 0.003) in comparison to control patients. TAVI led to an increase of TWI, but had no uniform enduring effect on StO 2 and THI. Tissue oxygenation StO 2 at both measurement sites correlated negatively with creatinine levels after TAVI at t2 (palm: ρ = −0.415; p = 0.009; fingertip: ρ = −0.519; p < 0.001) and t3 (palm: ρ = −0.427; p = 0.008; fingertip: ρ = −0.398; p = 0.013). Patients with higher THI at t3 reported higher physical capacity and general health scores 120 days after TAVI. Conclusion HSI is a promising technique for periinterventional monitoring of tissue oxygenation and microcirculatory perfusion quality, which are related to kidney function, physical capacity, and clinical outcomes after TAVI. Clinical trial registration https://drks.de/search/de/trial , identifier DRKS00024765.
No takes yet. Share an insight, caveat, or question.
Dietrich et al. (2023) studied this question.