Why the study?
Does a parametric program for 3D representation of bicuspid aortopathy provide wall shear stress estimates comparable to standard CTA reconstructions?
Does a parametric program for 3D representation of bicuspid aortopathy provide wall shear stress estimates comparable to standard CTA reconstructions?
A novel parametric program offers a rapid and automated tool for 3D anatomic representations of bicuspid aortopathy, yielding comparable wall shear stress estimates to standard CTA reconstructions.
Answers are grounded in this paper and cite their sources.
Time-consuming reconstruction limits routine computational modeling for BAV aortopathy; leaves open whether automated tools can enable clinical use.
Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely "bicuspid aortopathy") is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting from several measures derived by computed-tomography angiography (CTA). Assuming that wall shear stress (WSS) has an important implication on bicuspid aortopathy, computational flow analyses were then performed to estimate how different would such an important parameter be, if a parametric aortic geometry was used as compared to standard geometric reconstructions obtained by CTA scans. Morphologic parameters here documented can be used to rapidly model the aorta and any phenotypes of BAV. t-test and Bland-Altman plot demonstrated that WSS obtained by flow analysis of parametric aortic geometries was in good agreement with that obtained from the flow analysis of CTA-related geometries. The proposed program offers a rapid and automated tool for 3D anatomic representations of bicuspid aortopathy with promising application in routine clinical practice by reducing the amount of time for anatomic reconstructions.
No takes yet. Share an insight, caveat, or question.
Pasta et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: