Does optimizing AV delay improve Doppler index and plasma ANP levels compared to prolonged AV delay in patients with AV block and implanted DDD pacemakers?
Does optimizing AV delay improve Doppler index and plasma ANP levels compared to prolonged AV delay in patients with AV block and implanted DDD pacemakers?
Optimizing AV delay in patients with DDD pacemakers significantly improves combined systolic and diastolic myocardial performance as measured by Doppler index and reduces plasma ANP levels.
Answers are grounded in this paper and cite their sources.
May support AV delay optimization for better hemodynamics in DDD-paced patients; leaves open effects on clinical outcomes.
Doppler index is the sum of isovolumetric contraction time and isovolumetric relaxation time divided by ejection time and has clinical value as an index of combined systolic and diastolic myocardial performance. This crossover study compared the Doppler index and atrial natriuretic hormone (atrial natriuretic peptide) [ANP] between optimal (AV) delay and prolonged AV delay in patients with DDD pacemakers. The study included 14 patients (6 men, 8 women, age 78.4+/-9.3 [SD] years) with AV block with an implanted DDD pacemaker. AV delay was prolonged in a 25-ms, stepwise fashion starting from 125 ms to 250 ms. Pacing rate was set at 70 beats/min. Cardiac output (CO) was assessed by pulsed Doppler echocardiography, and optimal AV delay was defined as the AV delay at which CO was maximum, and an AV delay setting of 250 ms as prolonged AV delay. Plasma level of ANP and Doppler index determined by echocardiography were measured 1 week after programming. AV delay was switched to another AV delay and measurements were repeated after 1 week. Optimal AV delay was 159+/-19 ms. Doppler index was significantly lower at optimal AV delay than at prolonged AV delay (0.68+/-0.26 vs 0.92+/-0.30, P < 0.05). The plasma ANP level was significantly lower at optimal AV delay than at prolonged AV delay (29.0+/-30.7 vs 52.6+/-44.9 pg/mL, P < 0.05). In conclusion, the Doppler index and the plasma ANP level were significantly lower at optimal AV delay than at prolonged AV delay. This study shows the importance of the optimal AV delay setting in patients with an implanted DDD pacemaker, the Doppler index and plasma ANP levels are good indicators for optimizing AV delay.
No takes yet. Share an insight, caveat, or question.
Toda et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: