Does enclosed zone flow-mediated vasodilation (ezFMD) using an oscillometric method correlate with conventional ultrasonographic FMD for the assessment of endothelial function?
Does enclosed zone flow-mediated vasodilation (ezFMD) using an oscillometric method correlate with conventional ultrasonographic FMD for the assessment of endothelial function?
ezFMD using an oscillometric method is a simple, noninvasive alternative that significantly correlates with conventional ultrasonographic FMD for assessing endothelial function.
Answers are grounded in this paper and cite their sources.
Should not yet change endothelial testing practice; leaves open whether ezFMD improves risk prediction or outcomes.
BACKGROUND: It is clinically important to estimate the degree of endothelial dysfunction. Several methods have been used to assess endothelial function in humans. Recently, we developed a new noninvasive method for measurement of vascular response to reactive hyperemia in the brachial artery, named enclosed zone flow-mediated vasodilation (ezFMD). The purpose of this study was to determine the validity of ezFMD for assessment of endothelial function. METHODS AND RESULTS: We measured ezFMD by a new device using an oscillometric method and conventional FMD using ultrasonography in 306 subjects, including patients with hypertension, dyslipidemia, and diabetes mellitus (218 men and 88 women, 30 ± 16 yr). Univariate regression analysis revealed that ezFMD significantly correlated with age (r = -0.42, P < 0.0001), body mass index (r = -0.13, P = 0.028), systolic blood pressure (r = -0.15, P = 0.009), diastolic blood pressure (r = -0.14, P = 0.011), fasting glucose level (r = -0.27, P = 0.006), smoking (r = -0.21, P = 0.007) and baseline pulse wave amplitude (r = -0.51, P < 0.0001). ezFMD significantly correlated with conventional FMD (r = 0.34, P < 0.0001). Multiple regression analysis revealed that age (P = 0.002), body mass index (P = 0.013), systolic blood pressure (P = 0.009), smoking (P = 0.004) and baseline pulse wave amplitude (P < 0.001) were independent predictors of ezFMD. CONCLUSIONS: These findings suggest that measurement of ezFMD, a novel noninvasive and simple method, may be useful for determination of vascular diameter response to reactive hyperemia. Since ezFMD is automatically measured by a device with an oscillometric method, measurement of ezFMD is easier and less biased than that of conventional FMD.
No takes yet. Share an insight, caveat, or question.
Idei et al. (2013) studied this question.