Why the study?
Does a saline flush technique prolong time to peak aortic enhancement and save contrast medium during thoracic helical CT?
Does a saline flush technique prolong time to peak aortic enhancement and save contrast medium during thoracic helical CT?
Using a 12 ml saline flush after contrast injection during thoracic CT significantly prolongs peak aortic enhancement, allowing for a 12 ml reduction in contrast volume.
Answers are grounded in this paper and cite their sources.
May allow 12 ml contrast reduction in thoracic CT via saline flush; leaves open need for randomized trials to confirm benefit.
PURPOSE: The purpose of this work was to investigate the volume of contrast medium saved by the saline flush technique. METHOD: Thoracic helical CT was performed by injecting 75 ml of contrast material (Ioversol 320) only (n = 25; Group A) or 75 ml of contrast medium pushed with 6 ml (n = 25; Group B), 12 ml (n = 25; Group C), 25 ml (n = 25; Group D), or 50 ml (n = 25; Group E) of saline at a rate of 2 ml/s. The aortic CT numbers were measured from 30 to 55 s after the beginning of injection. We compared the time to peak aortic enhancement (TPAE) among Groups A-E. RESULTS: The TPAEs of the Groups A-E were 42.6, 45.2, 48.6, 48.4, and 48.3 s, respectively, and there was a statistically significant difference among them (p < 0.0001, analysis of variance). Post hoc test revealed statistically significant differences in TPAE between Groups A and B, C, D, and E and between Groups B and C, D, and E but no differences among Groups C, D, and E. CONCLUSION: The saline flush technique prolongs TPAE by 6 s and saves 12 ml of contrast medium.
No takes yet. Share an insight, caveat, or question.
Irie et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: