Why the study?
Does a combination of SVM and nonstandard HRV measures accurately detect congestive heart failure?
Does a combination of SVM and nonstandard HRV measures accurately detect congestive heart failure?
Answers are grounded in this paper and cite their sources.
A novel machine learning approach using SVM and nonstandard HRV measures achieved 100% accuracy, sensitivity, and specificity in detecting congestive heart failure in this dataset.
Heart rate variability (HRV) analysis has quantified the functioning of the autonomic regulation of the heart and heart's ability to respond. However, majority of studies on HRV report several differences between patients with congestive heart failure (CHF) and healthy subjects, such as time-domain, frequency domain and nonlinear HRV measures. In the paper, we mainly presented a new approach to detect congestive heart failure (CHF) based on combination support vector machine (SVM) and three nonstandard heart rate variability (HRV) measures (e.g. SUM_TD, SUM_FD and SUM_IE). The CHF classification model was presented by using SVM classifier with the combination SUM_TD and SUM_FD. In the analysis performed, we found that the CHF classification algorithm could obtain the best performance with the CHF classification accuracy, sensitivity and specificity of 100%, 100%, 100%, respectively.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: