Does two-dimensional strain echocardiography correlate with tissue Doppler derived strain echocardiography in patients with amyloid cardiomyopathy and healthy volunteers?
Does two-dimensional strain echocardiography correlate with tissue Doppler derived strain echocardiography in patients with amyloid cardiomyopathy and healthy volunteers?
Two-dimensional strain echocardiography provides strain measurements that correlate closely with established tissue Doppler methods, supporting its feasibility for routine clinical deformation analysis.
Answers are grounded in this paper and cite their sources.
Supports 2D strain feasibility in amyloid cardiomyopathy; leaves open prospective outcome validation versus TD-SE.
BACKGROUND: Two-dimensional strain echocardiography (2D-SE) calculates tissue velocities via frame-to-frame tracking of unique acoustic markers within the image and provides strain parameters in two dimensions. Novel 2D-SE software allows semi-automated strain measurements and increased averaging capabilities optimizing signal-noise ratio. AIM: We tested whether 2D-SE and the currently used and well-validated tissue Doppler derived strain echocardiography (TD-SE) yield similar information in the clinical setting. METHODS AND RESULTS: We performed 2D-SE and TD-SE on 17 patients with amyloid cardiomyopathy and 10 age-matched healthy volunteers. Single walls from standard apical views (2- and 4-chamber) were acquired at high frame rates ( approximately 200fps). Offline analysis was performed by observers blinded to clinical data using the EchoPAC program with custom 2D-SE software. Longitudinal strain rate and strain from the basal, mid and apical segments of the septal and lateral walls were determined by each method (TD-SE and 2D-SE). Ejection fraction was >0.55 in healthy volunteers and ranged from 0.30 to 0.80 in cardiomyopathy group. A total of 54 walls (162 segments) were examined. Acceptable quality strain data was available in 92% and 85% segments by 2D-SE and TD-SE, respectively. Two-dimensional strain echocardiography values correlated closely with TD-SE values (r=0.94 and 0.96 for strain rate and strain, respectively). CONCLUSIONS: Deformation analysis by 2D-SE is feasible in a clinical setting and 2D-SE values correlate closely with TD-SE measurements over a wide range of global systolic function. Two-dimensional strain echocardiography may help to facilitate the routine clinical implementation of deformation analysis.
No takes yet. Share an insight, caveat, or question.
Modesto et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: