Does the peak frequency ratio (PFR) measurement accurately detect internal carotid artery stenosis?
Does the peak frequency ratio (PFR) measurement accurately detect internal carotid artery stenosis?
Pulsed Doppler with spectral analysis using the peak frequency ratio is a useful screening parameter for suspected internal carotid artery stenosis, whereas continuous-wave Doppler has an unacceptably high false-negative rate.
Answers are grounded in this paper and cite their sources.
Supports PD/SA for carotid stenosis screening; leaves open prospective validation before practice change.
The peak frequency ratio (PFR) between the internal carotid and common carotid artery Fast Fourier Transform Spectral Analysis patterns has been used to identify patients with internal carotid artery stenosis. To evaluate further the accuracy of the PFR, we applied it to the spectral analysis data from 396 vessels whose sound signals were obtained with a Duplex scanner (pulsed Doppler) and 246 arteries whose audible flow data were generated by a continuous-wave Doppler. The pulse Doppler with spectral analysis (PD/SA) correctly identified 221/254 (87%) of the vessels with less than 50% angiographic stenosis, 81/100 (81%) of the arteries with 50-99% stenosis, and 35/42 (83%) of the totally occluded internal carotid vessels for an overall accuracy of 85%. The continuous-wave Doppler with spectral analysis (CW/SA) did well in two categories but had an unacceptably high 47% false-negative rate for arteries with 50-99% stenosis. The PFR when applied to PD/SA test results is a useful parameter in screening patients with suspected internal carotid artery stenosis.
No takes yet. Share an insight, caveat, or question.
Keagy et al. (1982) studied this question.