Answers are grounded in this paper and cite their sources.
Aqueous absorption/stripping is the state-of-the-art technology for the capture of CO 2 from coal-fired power plants. This technology is energy-intensive and has been applied to CO 2 removal from natural gas, ammonia, and hydrogen gas streams. Energy requirements can be reduced by the use of a more-reactive solvent, operating the cross exchanger at a lower temperature, optimizing the stripper operation, and using innovative stripper configurations (vacuum and multipressure). This work calculates stripper performance with an algorithm in Aspen Custom Modeler (ACM) that incorporates thermodynamic studies, reaction rate measurements, physical properties, and contactor-specific information for three stripper configurations a simple stripper operating at 160 kPa, a multipressure stripper operating at three pressures (330/230/160 kPa), and a vacuum stripper (30 kPa) for two solvents: 7 m (30 wt %) monoethanolamine (MEA) and 5 m K + /2.5 m piperazine. The temperature approach is varied from 5 to 10 °C. With some approximations, we predict the influence of using solvents with varying heats of desorption (Δ H des ) on the reboiler duty and the equivalent work for stripping (reboiler duty as equivalent Carnot work plus compression work). With a rich solution giving P CO 2 * = 2.5 kPa at 40 °C, the vacuum stripper is favored for solvents with Δ H des ≤ 21 kcal/(gmol of CO 2 ) while the multipressure configuration is attractive for solvents with Δ H des ≥ 21 kcal/(gmol of CO 2 ).
No takes yet. Share an insight, caveat, or question.
Oyenekan et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: